REV. A Page 17
Drop in Pan - AWS Fire Pits
CONVERTING TO LP GAS
Pilot
Converstion Kit
Btu Ratings
LP Orifice
Models
FG-AWS-PBO-P
50,000
(14.65kW)
OAS-LP47
LOF-2406FTAWS-N
LOF-3006FTAWS-N
FG-AWS-PBO-P
75,000
(21.98kW)
OAS-LP41
LOF-3606FTAWS-N
LOF-2412FHAWS-N
FG-AWS-PBO-P
100,000
(29.30kW)
OAS-LP35
LOF-4806FTAWS-N
LOF-3012FHAWS-N
FG-AWS-PBO-P
125,000
(36.63kW)
OAS-LP31
LOF-6006FTAWS-N
LOF-3614FHAWS-N
FG-AWS-PBO-P
150,000
(43.96kW)
OAS-LP29
LOF-7206FTAWS-N
LOF-4814FHAWS-N
FG-AWS-PBO-P
175,000
(51.28kW)
OAS-LP26
LOF-8406FTAWS-N
LOF-6016FHAWS-N
FG-AWS-PBO-P
200,000
(58.61kW)
OAS-LP22
LOF-9606FTAWS-N
LOF-7216FHAWS-N
FG-AWS-PBO-P
225,000
(65.94kW)
OAS-LP19
LOF-8416FHAWS-N
FG-AWS-PBO-P
250,000
(73.26kW)
OAS-LP12
LOF-9616FHAWS-N
Table 6
LP Conversion Chart
Gas
Supply
Non-Combustible Enclosure
Burner
Key Valve
LEARN
Weather
Proof
Box
Weather
Proof
Box
Red
Red
Red
Red(+)
Black (-)
Red
Black
Red Sleeve
FG-1420-AOD
Receiver
GOE-30VDC
Power Supply
Heat
Shield
120VAC
Power GFI
Outlet
Orifice
Flat Pan
Pilot
When converting a Natural Gas (NG) model to Liquid Propane (LP) you must change the pilot orifice and the main burner
orifice. See Table 6 for the pilot kit and LP orifice for your model.
Note
: These items must be purchased seperately.
Fig. 12
Shows location of main burner orifice and pilot assembly.