background image

REV. 2-4-19 Page 13

Linear Outdoor Fire (LOF)

MAINTENANCE 

1.  The Linear Outdoor Fire should be inspected and cleaned before initial use annually by a qualified field service per-

son.

2.  Any component that is found faulty must be replaced with an approved component.

3.  Any tampering or modifying with the Linear Outdoor Fire is dangerous and voids all warranties.

4.  During winter months in cold climates and various seasons operation the Linear Outdoor Fire may be affected by 

weather conditions.  It is recommended to use a ventilated cover overtop of your Linear Outdoor Fire to protect it from 

humid/rainy weather conditions when not in use.  Heavy rains/downpours could affect the Linear Outdoor Fire opera-

tion if not covered; if this occurs ensure you allow the Linear Outdoor Fire time to dry out before attempting to operate.  

NOTE

: If a combustible type cover is used over the Linear Outdoor Fire when not in use be sure to remove it before 

operation to prevent a severe safety hazard.

5.  Carbon (soot) may build up on the surface of logs (if installed) during heavy use.  Sooting may also occur periodically   

 on the screen of the ignitor hood.  To clean, brush off with a dry bristle brush or cloth.  Keep soot away from clothing 

of furniture.  

6.  Over time stainless steel parts discolor when heated, usually a golden or brown hue.  This discoloration is normal and   

 does not affect the performance of the appliance.

TROUBLE SHOOTING

Symptom

  

Remedy

Unit Won’t Light  

1. Ensure key valve is fully open.

 

 

 

2. Bleed gas line.

 

 

 

3. Ensure all gas supply lines are turned ON.

 

 

 

4. Ensure there is not too much media overtop of burner; it can inhibit gas from flowing.

 

 

 

5. Ensue E-Stop if turned ON (if applicable).

Low Flame 

 

1. Ensure the media is at least 1-inch in diameter and top media is no more than 1-inch over

 

 

 

    top of burner.

 

 

 

2. Adjust air shutter at bottom of Linear Outdoor Fire pit pan.

 

 

 

3. Ensure all shut-off valves and key valve is fully open.  See page 11; Fig. 7.

Water in Fire Pit  

1. Excess dust/sand material from media may be blocking the weep holes to relieve water.          

 

 

                 Remove all media and unplug weep holes.  Clean or install new media free of dust and dirt.

 

 

 

2. Ensure Linear Outdoor Fire pit enclosure has proper drainage for water and proper ventilation    

 

 

 

    to dry out.

Summary of Contents for LOF-30MTN

Page 1: ...IANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION PRECAUTION This Linear Outdoor Fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Natural Gas Description LOF 30MT N 30 inch stainless tube burner pan LOF 36MT N 36 inch stainless tube burner pan MODELS ...

Page 2: ...ve unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury of property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions is not fo...

Page 3: ...impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave the area allowing any moisture in the media to dissipate We strongly recommend that during t...

Page 4: ...1 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model Min Max Opening Width Length A Pan Depth B Outside Pan C Inside Pan D Ground Level E Combustible Floor LOF 30MT N 6 7 W x 30 31 L 2 32 x 8 30 x 6 6 18 LOF 36MT N 6 7 W x 36 37 L 2 38 x 8 36 x 6 6 18 Note Linear Outdoor Fire s are rated at maximum Btu s which is dependent upon proper gas pipe sizing Flex line size also affect Btu s As a r...

Page 5: ...red for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 1...

Page 6: ...ound the pipe with weather sealant 3 the primary shut off not supplied will reguire a 1 2 male flared fitting to enable connection of stainless steel flex IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of t...

Page 7: ...y Not approved for any indoor use 9 This Linear Outdoor Fire is designed to have Lava Rock Media completely covering the burner tube so that the burner is invisible Do not cover more than 1 above the top of the burner When purchasing Lava Rock it is recom mended to use minimum of 1 diameter as a base to fill the burner pan Decorative glass covering may be loosely scattered on top of the rock if de...

Page 8: ...s rated Teflon tape wrapped around the threads Thread the OAS orifice air shutter on to the nipple of the burning spur clockwise manner Secure into position See Fig 4 GAS FLOW Burner Pan OAS U3 8D S Lock Nut INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock media into the burner pan Ensure the media is a minimum of 1 inch diameter for proper operation Note Do not pour Lava Rock dir...

Page 9: ...ds Key Valve Key Fig 6 Typical Installation Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non...

Page 10: ... Key Valve U1 8D S U1 8D S Fitting Inlet Gas Supply Expanded View of Match Throw LOF Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 11: ...ting air passageways of the appliance be kept clean 5 Inspect the fuel supply connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause sever burns if contacted 2 Do not burn any solid fuels in this appliance MATCH ...

Page 12: ...1 WASHER10SS 5 1 2 Flex Gas Line 46 inch Length T 200 9898 46 6 Orifice Air Shutter LOF 30 NG 1 OAS NG36 6 Orifice Air Shutter LOF 30 LP 1 OAS LP49 6 Orifice Air Shutter LOF 36 NG 1 OAS NG29 6 Orifice Air Shutter LOF 36 LP 1 OAS LP41 7 Std Capacity Straight Ball Valve 1 BVL2S 8 12 inch Chrome Key for BVSL2S KEY PC 12 9 Chrome Flange decorative chrome cover for BVSL2S 1 CVR BVL2CP 10 1 2 MIP Brass ...

Page 13: ... the surface of logs if installed during heavy use Sooting may also occur periodically on the screen of the ignitor hood To clean brush off with a dry bristle brush or cloth Keep soot away from clothing of furniture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TROUBLE SHOOTING ...

Page 14: ...tion into the enclosure Model VENT 6X12SS LP Converstion Kits Model OAS 49 for LOF30 Model OAS 41 for LOF36 LIDS Stainless steel cover to protect fire pit when not in use Model LID LOF30 Model LID LOF36 Flexframe Universal brackets to support fire pit disc when using paver blocks or other non combustible enclosures Model FLEXFRAME SS Note Media such as Lava Rock or Lava Stoves are not supplied but...

Page 15: ...ther location or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemicals including salt either directly or in the atmosphere or very high humidity is not covered by this Limited Warranty There are no other express warranties except as set forth herein For consumer...

Page 16: ... Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 ...

Reviews: