background image

REV. 2-4-19 Page 15

Linear Outdoor Fire (LOF)

Skytech Products Group (Firegear Outdoors) hereby warrants 

to the end user that products will be free from material and 

workmanship defects that prevent safe and correct operation of 

the product. The warranty commences from date of sale to the 

end user for the following period:

End User must provide a bill of sale, canceled check, or payment 

record from the end user to verify purchase date and to establish 

warranty period. This Limited Warranty shall be valid and limited 

to the original purchaser only.

WARNING Any modification to the product will void the warranty.

This Limited Warranty shall be limited to the repair and/or 

replacement of parts that have proven to be defective under 

normal use and service. Before returning any parts, contact 

our Technical Service Department for a Return Materials 

Authorization (RMA) number. All warranty claims must be made 

by the OEM / Distributor / Dealer account on behalf of the end 

user. You may contact Technical Service at (855) 498-8324.
All approved returned defects must be confirmed by our 

Technical Service Department. If the defect is confirmed and we 

approve the claim, we will replace such parts without charge. 

This warranty gives you specific legal rights, and you may also 

have other rights, which vary from state to state.

Travel, diagnostic cost, service labor to repair the defect and 

freight charges on warranty parts to and from the factory will 

be responsibility of the owner. We will not be responsible for 

labor charges and/or damage incurred in installation, repair, and 

replacement.

LIMITED WARRANTY

This Limited Warranty is voided if not assembled, installed 

and operated as intended. This Limited Warranty does not 

cover any defects due to accident, abuse, misuse, alteration, 

misapplication, vandalism, improper installation or improper 

maintenance or service, removal from the original location or 

re- installation into another location, or failure to perform normal 

and routine maintenance.

Damage due to severe weather conditions such as hail, 

hurricanes, earthquakes, tornadoes, discoloration due to over-

heating, exposure to chemicals (including salt), either directly or 

in the atmosphere, or very high humidity, is not covered by this 

Limited Warranty.

There are no other express warranties except as set forth herein. 

For consumer applications, any applicable implied warranties of 

merchantability and fitness are limited induration to the period 

of coverage of this Limited Warranty. Some states do not allow 

limitation on how long an implied warranty lasts, so this limitation 

may not apply to you.

For Commercial applications, the liability of Firegear Outdoors 

is limited to the express terms of this warranty. We expressly 

disclaim any and all implied warranties, including any warranties 

of fitness for a particular purpose or merchantability.

We are not liable for any special, indirect or consequential 

damages. Our maximum liability is limited to the purchase 

price of the purchased products. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so 

this limitation or exclusions may not apply to you.

We do not authorize any person or company to assume for it any 

other obligation or liability in connection with the sale, installation, 

use, removal, return, or replacement of its equipment; and no 

such representations are binding.

Lava Rock and Lava Stones are not

 covered by warranty

CONSUMER/NON-COMMERCIAL APPLICATIONS:
Stainless Steel Components

5 Years

Gas Valve, Spark Igniter & Electronic Parts

2 Years

Log Sets

5 Years

Glass Windshields

5 Years

Glass Media

1 Year

Controls

5 Years

AnF Enclosures

5 Years

GFRC (Glass Fiber Reinforced Concrete)

1 Year

COMMERCIAL APPLICATIONS:
Stainless Steel Components

1 Year

Gas Valve, Spark Igniter & Electronic Parts

1 Year

Log Sets

1 Year

Glass Windshields

1 Year

Glass Media

1 Year

Controls

1 Year

AnF Enclosures

1 Year

GFRC (Glass Fiber Reinforced Concrete)

1 Year

Lava Rock and Lava Stones are not

 covered by warranty

A DIVISION OF SKYTECH PRODUCTS GROUP

REV. 6/18

Summary of Contents for LOF-30MTN

Page 1: ...IANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION PRECAUTION This Linear Outdoor Fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Natural Gas Description LOF 30MT N 30 inch stainless tube burner pan LOF 36MT N 36 inch stainless tube burner pan MODELS ...

Page 2: ...ve unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury of property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions is not fo...

Page 3: ...impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave the area allowing any moisture in the media to dissipate We strongly recommend that during t...

Page 4: ...1 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model Min Max Opening Width Length A Pan Depth B Outside Pan C Inside Pan D Ground Level E Combustible Floor LOF 30MT N 6 7 W x 30 31 L 2 32 x 8 30 x 6 6 18 LOF 36MT N 6 7 W x 36 37 L 2 38 x 8 36 x 6 6 18 Note Linear Outdoor Fire s are rated at maximum Btu s which is dependent upon proper gas pipe sizing Flex line size also affect Btu s As a r...

Page 5: ...red for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 1...

Page 6: ...ound the pipe with weather sealant 3 the primary shut off not supplied will reguire a 1 2 male flared fitting to enable connection of stainless steel flex IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of t...

Page 7: ...y Not approved for any indoor use 9 This Linear Outdoor Fire is designed to have Lava Rock Media completely covering the burner tube so that the burner is invisible Do not cover more than 1 above the top of the burner When purchasing Lava Rock it is recom mended to use minimum of 1 diameter as a base to fill the burner pan Decorative glass covering may be loosely scattered on top of the rock if de...

Page 8: ...s rated Teflon tape wrapped around the threads Thread the OAS orifice air shutter on to the nipple of the burning spur clockwise manner Secure into position See Fig 4 GAS FLOW Burner Pan OAS U3 8D S Lock Nut INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock media into the burner pan Ensure the media is a minimum of 1 inch diameter for proper operation Note Do not pour Lava Rock dir...

Page 9: ...ds Key Valve Key Fig 6 Typical Installation Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non...

Page 10: ... Key Valve U1 8D S U1 8D S Fitting Inlet Gas Supply Expanded View of Match Throw LOF Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 11: ...ting air passageways of the appliance be kept clean 5 Inspect the fuel supply connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause sever burns if contacted 2 Do not burn any solid fuels in this appliance MATCH ...

Page 12: ...1 WASHER10SS 5 1 2 Flex Gas Line 46 inch Length T 200 9898 46 6 Orifice Air Shutter LOF 30 NG 1 OAS NG36 6 Orifice Air Shutter LOF 30 LP 1 OAS LP49 6 Orifice Air Shutter LOF 36 NG 1 OAS NG29 6 Orifice Air Shutter LOF 36 LP 1 OAS LP41 7 Std Capacity Straight Ball Valve 1 BVL2S 8 12 inch Chrome Key for BVSL2S KEY PC 12 9 Chrome Flange decorative chrome cover for BVSL2S 1 CVR BVL2CP 10 1 2 MIP Brass ...

Page 13: ... the surface of logs if installed during heavy use Sooting may also occur periodically on the screen of the ignitor hood To clean brush off with a dry bristle brush or cloth Keep soot away from clothing of furniture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TROUBLE SHOOTING ...

Page 14: ...tion into the enclosure Model VENT 6X12SS LP Converstion Kits Model OAS 49 for LOF30 Model OAS 41 for LOF36 LIDS Stainless steel cover to protect fire pit when not in use Model LID LOF30 Model LID LOF36 Flexframe Universal brackets to support fire pit disc when using paver blocks or other non combustible enclosures Model FLEXFRAME SS Note Media such as Lava Rock or Lava Stoves are not supplied but...

Page 15: ...ther location or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemicals including salt either directly or in the atmosphere or very high humidity is not covered by this Limited Warranty There are no other express warranties except as set forth herein For consumer...

Page 16: ... Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 ...