REV. 2-4-19 Page 4
Linear Outdoor Fire (LOF)
SPECIFICATIONS
Table1
LOF Pan Dimensions
Ground Level
A
B
C
D
End View
Fig. 1
Linear Pan Dimensions; refer to Table 1.
Fig. 2
Clearance to Combustibles (Not
to be used in an enclosed space)
Model
Btu’s
NG/(LP)
Factory Orifice
NG LP
LOF-30MT-N 45,000 Btu’s
#36
#49
LOF-36MT-N 75,000 Btu’s
#29
#41
Pressure
NG
LP
Min. Inlet
5.0”WC
11.0”WC
Max. Inlet 10.5”WC 13.0”WC
Table 3
Gas Pressures
Model
Min/Max Opening Width - Length
A
Pan
Depth
B
Outside
Pan
C
Inside
Pan
D
Ground
Level
E
Combustible
Floor
LOF-30MT-N
6 ¼”- 7 ½” W x 30 ¼”- 31 ¾” L
2 ¾”
32” x 8” 30” x 6”
6”
18”
LOF-36MT-N
6 ¼”- 7½” W x 36 ¼”- 37 ¾” L
2 ¾”
38” x 8” 36” x 6”
6”
18”
Note:
Linear Outdoor Fire’s are rated at maximum Btu’s which is
dependent upon proper gas pipe sizing. Flex line size also affect Btu’s.
As a result your Btu’s will may vary from Table 2 specifications listed above.
Table 2
Btu Specifications based on 7.0”WC - NG and 10.0”WC -LP
96”
36”
18”
CL
24”
Max
Overhang