4
OD42 Outdoor Gas Fireplace
SAFETY LABEL
This is a copy of the label that accompanies each
OD42 Outdoor Fireplace. We have printed a copy
of the contents here for your review.
NOTE:
Firegear
Outdoors units are constantly being
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fi tter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
383
383
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
Listed:
Certified for/Certifi e pour:
Tested to:
OUTDOOR GAS FIREPLACE /
CANADA and U.S.A.
FOYER À GAZ EXTÉRIEUR
IAS 4-96 (US) / CGA CR97-003 (CAN)
4001172
é
CAN/CGA-2.17-M91 /
.
NOT FOR USE WITH SOLID FUELS.
/
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
É
É
é
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le NFOD42
PROPANE GAS: Model NFOD42-P
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Maximum supply pressure
NATURAL GAS: Model NFOD42-N
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit
maximum selon
l'altitude
Pression d'allimentation maximum
Calorifique
é
é
é
é
14”
WC/C.E. (3.49 kPa)
5"
WC/C.E. (1.25 kPa)
WC/C.E.
44,500 Btu/h
(13.04 kW)
3.5"
(0.87kPa)
#29
DMS
0-4500
ft/pi
(0-1372 m)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit
maximum selon
l'altitude
Pression d'allimentation maximum
Calorifique
é
é
é
é
14"
WC/C.E. (3.49 kPa)
11”
WC/C.E. (2.74 kPa)
WC/C.E.
43,500 Btu/h
(12.74 kW)
10"
(2.49kPa)
#47
DMS
0-4500
ft/pi
(0-1372 m)
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Maximum supply pressure
D
E
F
A
B
C
Side Walls
A
11” (279mm)
B
36” (914mm)
C
18”(457mm)
D
12” (305mm)
E
57" (1448mm)
F
36" (914mm)
Ceiling
Min. Mantel Height
Max. Mantel Depth
Alcove Width
Alcove Depth
The installation must conform with local codes or, in the absence of local codes, with
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70.
This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, avec CAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54. L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en
l'absence de codes locaux, avec le Code canadien de l'électricité, CSA C22.1 ou avec le National Electrical Code, ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel du propriétaire pour les détails.
CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le NFOD42
é
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
919-002
NFOD42-P
NFOD42-N
Fire Gear LLC, P.O. Box 871250, Canton, MI 48197
Manufactured by: FPI Fireplace Products International Ltd.
6988 Venture St. Delta, BC, Canada V4G 1H4
Summary of Contents for OD42-N
Page 5: ...OD42 Outdoor Gas Fireplace 5 DIMENSIONS UNIT DIMENSIONS WITH 2 FACEPLATE ...
Page 6: ...6 OD42 Outdoor Gas Fireplace DIMENSIONS UNIT DIMENSIONS WITH 4 FACEPLATE ...
Page 36: ...36 OD42 Outdoor Gas Fireplace NOTES ...
Page 37: ...OD42 Outdoor Gas Fireplace 37 NOTES ...