background image

Fireblitz Extinguisher Ltd 

Units 15/17 Manford Industrial Estate, Manor Road, Erith, Kent DA8 2AJ.

Tel: 01322 342238   

|

   Fax: 01322 331532   

|

   Email: sales@fireblitz.co.uk   

|

   www.fireblitz.co.uk

Fireblitz reserve the right to change the design or specification details without prior notice.

REF: COL&S 01/2021

GUIDE TO

Smoke & Heat 

Alarm Location

SMOKE ALARMS

HEAT ALARMS

BEDROOM

BEDROOM

BEDROOM

BASEMENT

LOUNGE

KITCHEN

GARAGE

CORRECT LOCATION IS IMPERATIVE IF 

NUISANCE ALARMS ARE TO BE AVOIDED!

 

  SMOKE ALARM FOR MINIMUM PROTECTION

 

  SMOKE ALARM FOR INCREASED PROTECTION

 

  HEAT ALARMS

Do NOT 

place in a draft. 

Do NOT 

place near bathrooms 

and showers

Do NOT

 place in kitchens - use 

heat alarms there

KEEP AWAY

 from vents or 

extractor fans

Do NOT 

place directly above 

heaters, radiators or in front of 

air conditioning units

Do NOT 

place in insect infested 

areas (attics, garages etc) - use 

heat alarms there

KEEP 300mm AWAY

 from 

lights that generate heat. 

(Tungsten and low voltage bulbs)

KEEP AWAY 

from objects that 

could divert or prevent smoke 
from reaching them, ie beams 

and other ceiling features.

REMEMBER

, heat alarms need a fire to activate, 

flames 

WILL

 be present.

Do NOT 

install on walls

Do NOT 

use in escape routes

ALWAYS

 interlink to smoke alarms

Do NOT 

use in lounges, bedrooms  and separate 

dining rooms where smoke alarms are best

AVOID

 use in areas where children, the elderly and 

disabled are normally present

DESIGNED

 for kitchens, garages, cellars, attics where 

steam, vapours, dust, and cobwebs may cause nuisance 

alarms from smoke alarms

KEEP 300mm AWAY

 from lights and appliances 

that generate heat. (Tungsten and low voltage bulbs) 

(Sensor temperature  range 54°C – 65°C )

KEEP AWAY

 from objects that could divert or prevent 

smoke and heat from reaching them, ie beams and 

other ceiling features.

KEEP AWAY

 from extractor fans

Summary of Contents for FH150

Page 1: ...the design or specification details without prior notice REF COL S 01 2021 Important information FH150 155 160 Compact design TSE Technology FHB10 FEATURING X Profile TSE Technology FHB10W FEATURING X Profile TSE Technology FHH10 FEATURING Advanced THERMISTOR Protection FHH10W FEATURING Advanced THERMISTOR Protection FireHawk Smoke and Heat Alarms have a LOW BATTERY SILENCE Feature Pressing the TE...

Page 2: ...Do NOT place in insect infested areas attics garages etc use heat alarms there KEEP 300mm AWAY from lights that generate heat Tungsten and low voltage bulbs KEEP AWAY from objects that could divert or prevent smoke from reaching them ie beams and other ceiling features REMEMBER heat alarms need a fire to activate flames WILL be present Do NOT install on walls Do NOT use in escape routes ALWAYS int...

Page 3: ...REMOVING ALARM FROM BASE Fireangel base adaptor DICON base adaptor KIDDE base adaptor Plugs and screws Sticky pads Adhesive Often you ll find old bases from other smoke and heat alarm manufacturers perminantly fixed to ceilings We can provide you with base plate adaptors so that you can easily install FireHawk alarms to existing bases We recommend these three ways to fix your smoke or heat alarm b...

Page 4: ...x months clean the alarm with a damp cloth do not use spray or chemical cleaners and polishes In the event of a problem contact our helpline 0800 008 6568 TROUBLE SHOOTING Be sure which alarm has been the problem upstairs downstairs heat or smoke Are the alarms interlinked If so check which one has a fast flashing red light during an alarm that s the one that has set the system off Where is it ins...

Page 5: ... if the battery power is weak GENERAL FAULT Double beep every minute TEST BUTTON JAMMED Single beep every 11 seconds TEST Red LED flashes twice every second plus a series of three beeps ALARM SILENCE Red LED flashes once every 10 seconds FULL ALARM Red LED flashes twice every second plus a series of three beeps every 4 seconds EVACUATE THE PROPERTY IMMEDIATELY AND CALL THE EMERGENCY SERVICES FH150...