Finalizing
the
Installation
(for qualified installers only)
19
© Travis Industries
4161018
100-01436
Insulated Chimney – Alternative Manufacturers
The following list chimney brand/series have been reviewed and are compatible with this fireplace.
Manufacturer
Chimney
Series
Anchor Plate
Outside
Diameter
Clearance*
Notes
Duravent
DTC
7DTC-AP
9” ---
2”
Duravent
Duraplus HTC
C9101 7HTC-BP
11”
2”
ICC
EXCEL 7”
EAP7
9-1/4”
2”
Security
Oliver
MacLeod
6007AP
6107AP
9”
9-9/10”
2”
2”
---
Security
ASHT+ (S2100+)
XSP
9”
2”
Tabs on anchor plate must
be removed (or order
Travis # 98900290)
Selkirk
CF Sentinel
SuperVent 2100JM
SuperPro 2100 ALT
UltimateOne
7CF-AP
JM7AP
JM7AP
7U1-AP
11-3/4”
11”
11”
9” ---
2”
2”
2”
2”
---
Metal-Fab **
Temp Guard 2100
7TGAP
10”
2” **
--
* See pipe manufacturer’s instructions for details on installation and minimum framing dimensions.
**
NOTE
: This chimney requires a 2” clearance when used with the 42 Apex (disregard the 1-1/2”
clearance listed on the chimney).
Anchor Plate Installation
Each chimney system requires an anchor plate. Attach the plate to the top of the fireplace with the
four included sheet-metal screws (see illustration below).
NOTE
: each anchor plate may have a slightly different mounting hole location. Before attaching the
anchor plate, pre-drill the holes for the mounting screws (the screw penetrates two layers of steel).
Seal the fireplace connection with high-temperature silicone.
Seal the flue liner with furnace cement.
High-Temperature
Silicone
Use high-temperature silicone to
seal the anchor plate.
Furnace Cement