3.20 Setup for MIG (FCAW) Welding with Flux Core (Gasless) Wire
A. Select MIG mode with the process selection control (refer to Section 3.10.12 for further information).
B. Connect the MIG Gun Polarity Lead to the negative welding terminal (-). If in doubt, consult the electrode wire manufacturer.
Welding current flows from the Power Source via Dinse style connectors. It is essential, however, that the male plug is
inserted and turned securely to achieve a sound electrical connection.
C. Connect the work lead to the positive welding terminal (+). If in doubt, consult the electrode wire manufacturer. Welding
current flows from the Power Source via Dinse style connectors. It is essential, however, that the male plug is inserted
and turned securely to achieve a sound electrical connection.
D. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.
E. Switch the LOCAL/REMOTE switch inside the wire feed compartment to LOCAL to use the Power Sources Wirespeed
and Voltage controls.
WARNING
Before connecting the work clamp to the work piece, make sure you have ceased feeding wire so premature arcing
will not occur.
CAUTION
Loose welding terminal connections can cause overheating and result in the male plug being fused in the terminal.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding Power
Source.
Art# A-12521
MIG Gun
Polarity Lead.
Negative Welding
Terminal (-)
Positive Welding
Terminal (+)
MIG Gun
Work Lead
Figure 3-17: Setup for MIG (FCAW) Welding with Flux Cored (Gasless) Wire
Summary of Contents for MST 140i
Page 6: ...This Page Intentionally Blank ...
Page 76: ...Firepower MST 140i BASIC WELDING GUIDE 4 24 Manual 0 5338 This Page Intentionally Blank ...
Page 82: ...Firepower MST 140i KEY SPARE PARTS 6 2 Manual 0 5338 6 02 Power Source Art A 12518 31 ...
Page 86: ...Firepower MST 140i KEY SPARE PARTS 6 6 Manual 0 5338 This Page Intentionally Blank ...
Page 87: ...Firepower MST 140i Manual 0 5338 1 APPENDIX APPENDIX This Page Intentionally Blank ...
Page 89: ...Firepower MST 140i Manual 0 5338 3 APPENDIX Art A 12517 ...