SAFETY AND INSTALLATION
FIREPOWER 160 S
Manual 0-5371
3-3
Safety and Installation
3.02 Specifications
US Version
Power Source Part Number
1442-0037
Mains Power
Nominal Supply Voltage
AC 115V
AC 208/230V
Number of Phases
Single Phase
Single Phase
Input Voltage Range
AC 104- 127V
AC 187- 253V
Nominal Supply Frequency
50/60 Hz
50/60 Hz
Effective Input Current (l1eff)
16.7 Amps
12.7 Amps
Maximum Input Current (l1 max)
∆ 27.3 Amps
∆ 25 Amps
Single Phase Generator Requirements [Continuous
rating at nominal supply voltage with maximum output
for STICK (SMAW) welding]
4 KVA
6 KVA
Welding Output
Welding Current Range
10 - 110 Amps
10 - 160 Amps
Nominal DC Open Circuit Voltage (OCV)
71V
71V
Welding Output, 104º F (40º C), 10 min.
(Quoted figures refer to STICK (SMAW) output)
100A @ 30%, 24.0V
80A @ 60%, 23.2V
60A @ 100%, 22.4V
160A @ 30%, 26.4V
100A @ 60%, 24.0V
80A @ 100%, 23.2V
Rated Input Current (A)
27.3A
25A
for STICK (SMAW) Welding
Io = 100A @ 24.0V
Io = 160A @ 26.4V
Rated Input Current (A)
19A
15.5A
for LIFT TIG (GTAW) Welding
Io = 110A @ 14.4V
Io = 160A @ 16.4V
Rated Output for STICK (SMAW) Welding
24.0V, 100A @ 35%
26.4V, 160A @ 30%
Rated Output for LIFT TIG (GTAW) Welding
14.4V, 110A @ 50%
26.4V, 160A @ 30%
Duty Cycle (%)
30% @ 100A
30% @ 160A
Welder Type
Inverter Power Source
Output Terminal Type
Heavy Duty Dinse
TM
50
Classification
Protection Class
IP23S
Standards
EN 60974-1
EN50199
Cooling Method
Fan Cooled
Dimensions and Weight
Welding Power Source Mass
17.4 lb. (7.9 kg)
Welding Power Source Dimensions (Height x Width x
Depth)
H 9.0” x W 5.3” x D 15.5”
(H230mm x W135mm x D393mm)
∆
The recommended time delay fuse or circuit breaker size is 30 amp. An individual branch circuit capable of carrying 30
amperes and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than
200 percent of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)
Firepower continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously
sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above specifications
due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components, installation
location and conditions and local power grid supply conditions.
.
Summary of Contents for TIG 160S
Page 6: ...This Page Intentionally Blank ...
Page 18: ...FIREPOWER 160 S INTRODUCTION Introduction 2 2 Manual 0 5371 Notes ...
Page 30: ...FIREPOWER 160 S SAFETY AND INSTALLATION Safety and Installation 3 12 Manual 0 5371 Notes ...
Page 40: ...FIREPOWER 160 S THEORY OF OPERATION Theory of Operation 5 2 Manual 0 5371 Notes ...
Page 54: ...FIREPOWER 160 S TROUBLESHOOTING Troubleshooting 6 14 Manual 0 5371 Notes ...
Page 59: ...DISASSEMBLY PROCEDURE FIREPOWER 160 S Manual 0 5371 7 5 Disassembly Procedure 4 Art A 09866 ...
Page 66: ...FIREPOWER 160 S DISASSEMBLY PROCEDURE Disassembly Procedur 7 12 Manual 0 5371 Notes ...
Page 69: ...ASSEMBLY PROCEDURES FIREPOWER 160 S Manual 0 5371 8 3 Assembly Procedures 8 Art A 09883 ...
Page 74: ...FIREPOWER 160 S ASSEMBLY PROCEDURES Assembly Procedures 8 8 Manual 0 5371 Notes ...
Page 78: ...FIREPOWER 160 S REPLACEMENT PARTS Replacement Parts 9 4 Manual 0 5371 Notes ...
Page 80: ...FIREPOWER 160 S ACCESSORIES Accessories 10 2 Manual 0 5371 Notes ...
Page 83: ......