background image

 

 

FP-22408 

& 17310 

Fire Control Panel 

Operation and Maintenance Manual 

 

1.

 

Introduction............................................................................................................................................ 2

 

2.

 

Operation ............................................................................................................................................... 2

 

3.

 

Installation Procedure ............................................................................................................................. 3

 

 

Installation and Mounting........................................................................................................ 3

 

 

Power Supply 

 Connect directly to Battery .............................................................................. 3

 

 

Manual Activation Switches ..................................................................................................... 4

 

 

Linear Heat Detection Cable .................................................................................................... 4

 

 

Installation of FirePro Units 

 MAX 4 Units ............................................................................... 5

 

 

Thermal Fuse ......................................................................................................................... 5

 

 

Relay Connections and Programming ....................................................................................... 6

 

 

Sounder circuit wiring ............................................................................................................. 6

 

 

Extension Leads ..................................................................................................................... 6

 

 

Colour Coded Cables ............................................................................................................... 6

 

4.

 

Panel Operation ...................................................................................................................................... 7

 

 

Silence Alarms ........................................................................................................................ 7

 

 

Isolation Mode ....................................................................................................................... 7

 

5.

 

Maintenance ........................................................................................................................................... 7

 

 

TroubleShooting & Fault Codes ............................................................................................... 7

 

 

Replacing the Internal Battery ................................................................................................. 7

 

6.

 

Commissioning & Testing ........................................................................................................................ 8

 

7.

 

Component Description ........................................................................................................................... 9

 

8.

 

Specifications .......................................................................................................................................... 9

 

 

Summary of Contents for FP-22408

Page 1: ...tion Switches 4 Linear Heat Detection Cable 4 Installation of FirePro Units MAX 4 Units 5 Thermal Fuse 5 Relay Connections and Programming 6 Sounder circuit wiring 6 Extension Leads 6 Colour Coded Cab...

Page 2: ...il the FirePro generators are replaced SYSTEM OK INDICATOR will indicate green when the system is receiving appropriate 24vDC supply and is operating normally If power is not supplied or a fault if de...

Page 3: ...plug DO NOT force plugs The panel should not be placed in environments where the temperature is outside the range of 40 C to 66 C Mounting Bracket FP 22408B may be used This bracket will accommodate...

Page 4: ...the cables coming out of the Internal Activation Switch if no External Activation Switch is to be used Switch mechanism with travel Pin Switch Shown in External Mount Mount the Linear Heat Detection...

Page 5: ...he FirePro generator s to the panel using the Activation Circuit marked Yellow For risks that require two or more FirePro generators use the supplied splitter cable s USING Splitter Cables Using the s...

Page 6: ...d this needs to be specified by the installer To create extension leads follow these steps 1 Cut cable to required length and strip outer insulation to approximately 50mm Remove shielding and for 2 Pi...

Page 7: ...late the Model 17310 panel simply unplug the activation cable and this will put the panel into fault This should be done at the connection closest to the panel Control panels do not require any specif...

Page 8: ...Pro Generators and brackets are free from debris and any corrosion Ensure brackets are tight and show no signs of fatigue 5 Inspect Linear Heat Detection Cable ensuring it maintains a closed connectio...

Page 9: ...omes with installed Deutsch Plug for easy install FP 6200 Heavy Duty Bracket 316 SS Suits FP 100 200 500 FirePro Aerosol Generators FP 08960 Signage for the System A sheet of different size labels FP...

Page 10: ...icle ID Number Date of Installation FirePro Units Installed Specify Size and No of units Manual Activation Specify Location of Manual Actuation Switches Shutdown Installation Specify Delay Time and Sh...

Reviews: