FP-22408  Amerex AS5062 Vehicle Control Panel 

Operates

  on  10vDC-30vDC  power  supply  with  integrated  24hr 

backup battery.  Features:  

Automatic

 or Manual Activation. 

- Fires up to 4 FirePro Aerosol Generators. 
- 2x Detection Circuits;  1x Programmable Shutdown Relay. 
- Monitors all electrical circuits. 
- Vibration and weather proof and EMI/RFI resistant. 

 

 

FirePro Aerosol Generator 

100g 

 500g Unit. 

Constructed from Stainless Steel. 

Comes  with  installed  Deutsch  Plug 

for easy install.

 

 

FP-6200 

Heavy Duty Bracket 316 SS. 

Suits  FP-100,  200,  500  FirePro 
Aerosol Generators.

 

 

FP-08960 

Signage for the System.  A sheet of 

different size labels.

 

 

FP-08826 

Thermal Fuse 

Constructed from Stainless Steel.

 

 

FP-09510 

Linear Heat Detection Cable 182° C

 

 

FP-09511 

Linear  Heat  Detection  Installation 
kit.  Mounting  Clips,  2x  Junction 
Boxes with strain relief cable glands 
and 1x EOL for monitoring.

 

 

FP-09500 

2 Hour Fire Rated Shielded Cable.

 

 

FP-14016 

Battery Lead

 

 

FP-08912 

Wiring  loom  and  Splitter  Cable  for 

installaion  of  multiple  FirePro 
generators.

 

 

FP-08800 

FirePro  Simulator 

  for  Testing  & 

Commissioning.

 

 

 

Summary of Contents for FP-22408

Page 1: ...tion Switches 4 Linear Heat Detection Cable 4 Installation of FirePro Units MAX 4 Units 5 Thermal Fuse 5 Relay Connections and Programming 6 Sounder circuit wiring 6 Extension Leads 6 Colour Coded Cab...

Page 2: ...il the FirePro generators are replaced SYSTEM OK INDICATOR will indicate green when the system is receiving appropriate 24vDC supply and is operating normally If power is not supplied or a fault if de...

Page 3: ...plug DO NOT force plugs The panel should not be placed in environments where the temperature is outside the range of 40 C to 66 C Mounting Bracket FP 22408B may be used This bracket will accommodate...

Page 4: ...the cables coming out of the Internal Activation Switch if no External Activation Switch is to be used Switch mechanism with travel Pin Switch Shown in External Mount Mount the Linear Heat Detection...

Page 5: ...he FirePro generator s to the panel using the Activation Circuit marked Yellow For risks that require two or more FirePro generators use the supplied splitter cable s USING Splitter Cables Using the s...

Page 6: ...d this needs to be specified by the installer To create extension leads follow these steps 1 Cut cable to required length and strip outer insulation to approximately 50mm Remove shielding and for 2 Pi...

Page 7: ...late the Model 17310 panel simply unplug the activation cable and this will put the panel into fault This should be done at the connection closest to the panel Control panels do not require any specif...

Page 8: ...Pro Generators and brackets are free from debris and any corrosion Ensure brackets are tight and show no signs of fatigue 5 Inspect Linear Heat Detection Cable ensuring it maintains a closed connectio...

Page 9: ...omes with installed Deutsch Plug for easy install FP 6200 Heavy Duty Bracket 316 SS Suits FP 100 200 500 FirePro Aerosol Generators FP 08960 Signage for the System A sheet of different size labels FP...

Page 10: ...icle ID Number Date of Installation FirePro Units Installed Specify Size and No of units Manual Activation Specify Location of Manual Actuation Switches Shutdown Installation Specify Delay Time and Sh...

Reviews: