background image

Trouble shooting:

DO NOT disconnect battery to quieten an unwanted alarm. 

This will remove your protection. Fan the air or open a 

window to remove smoke or dust.

Problem

Trouble shooting

Smoke alarm does not sound 

when tested. NOTE: Push 

test button for at least five 

seconds while testing!

1.  Remove smoke alarm 

from bracket. Then check 

the battery is properly 

connect to battery 

connector.

2. Clean smoke alarm.

The alarm chirp occurs every 

about approx 32 seconds, 

at the same time as the red 

LED flash once

The battery is in low battery 

status, please replace battery, 

and refer to “replace battery” 

section.

Smoke alarm chirp occurs 

every approx 32 seconds, 

alarm goes into fault mode.

1.  Clean smoke alarm. Please 

refer to the “maintenance 

and cleaning” section.

2.  Purchase and change 

another smoke alarm if the 

problem still exist

Smoke alarm sounds 

unwanted alarms 

intermittently or when 

residents are cooking, taking 

showers, etc.

1.  Clean smoke alarm. Please 

refer to the “maintenance 

and cleaning” section.

2.  Move smoke alarm to a 

new location.

The alarm sounds different 

from it is used to. It starts 

and stops.

1:  This alarm is operating 

correctly.

2:  Clean smoke alarm. 

Please refer to the 

“maintenance and 

cleaning” section.

Warranty Information:

3-year limited smoke alarm warranty
Company warrants to the original consumer that each 

new smoke alarm to be free from defects in material and 

workmanship under normal use and service for a period of 3 

years from the date of purchase. This warranty does not cover 

damage resulting from accident, misuse or abuse or lack of 

reasonable care of the product.
In no case shall company be liable for any incidental or 

consequential damages for breach of this or any other 

warranty express or implied, whatsoever. The defective 

product can be mailed to the address on page 6 with details 

explaining the problem.

Where is the best place to install alarm:

•  At first you need install one unit in each bedroom and 

hallway. (see Diagram 3).

• Install it in the stairway and on every floor. (see Diagram 4)
•  Smoke, heat and burning things will spread horizontally 

after rising to the ceiling, so install the alarm in the middle 

of the ceiling of an ordinary structure house let the alarm 

induce every corner.

• Install an alarm in every bedroom.
•  Install an alarm in every room where large electrical 

appliances are operated (for example portable heaters ).

•  If the alarm cannot be installed in the middle of the ceiling 

for any reason, position the alarm at least 30cm away from 

the wall and corner of the room (see Diagram 5).

•  Put smoke alarm at both ends of a bedroom hallway or large 

room if the hallway or room is more than 9.1 m (30 ft) long.

•  Install smoke alarms on slopped, peaked or cathedral 

ceilings between 500 and 1500mm from the highest point 

of the ceiling. Smoke alarms in rooms with ceiling slopes 

greater than 1m in 8 m horizontally shall be located on the 

high side of the room (See Diagram 6)

Diagram 3

- 4 -