Trouble shooting:
DO NOT disconnect battery to quieten an unwanted alarm.
This will remove your protection. Fan the air or open a
window to remove smoke or dust.
Problem
Trouble shooting
Smoke alarm does not sound
when tested. NOTE: Push
test button for at least five
seconds while testing!
1. Remove smoke alarm
from bracket. Then check
the battery is properly
connect to battery
connector.
2. Clean smoke alarm.
The alarm chirp occurs every
about approx 32 seconds,
at the same time as the red
LED flash once
The battery is in low battery
status, please replace battery,
and refer to “replace battery”
section.
Smoke alarm chirp occurs
every approx 32 seconds,
alarm goes into fault mode.
1. Clean smoke alarm. Please
refer to the “maintenance
and cleaning” section.
2. Purchase and change
another smoke alarm if the
problem still exist
Smoke alarm sounds
unwanted alarms
intermittently or when
residents are cooking, taking
showers, etc.
1. Clean smoke alarm. Please
refer to the “maintenance
and cleaning” section.
2. Move smoke alarm to a
new location.
The alarm sounds different
from it is used to. It starts
and stops.
1: This alarm is operating
correctly.
2: Clean smoke alarm.
Please refer to the
“maintenance and
cleaning” section.
Warranty Information:
3-year limited smoke alarm warranty
Company warrants to the original consumer that each
new smoke alarm to be free from defects in material and
workmanship under normal use and service for a period of 3
years from the date of purchase. This warranty does not cover
damage resulting from accident, misuse or abuse or lack of
reasonable care of the product.
In no case shall company be liable for any incidental or
consequential damages for breach of this or any other
warranty express or implied, whatsoever. The defective
product can be mailed to the address on page 6 with details
explaining the problem.
Where is the best place to install alarm:
• At first you need install one unit in each bedroom and
hallway. (see Diagram 3).
• Install it in the stairway and on every floor. (see Diagram 4)
• Smoke, heat and burning things will spread horizontally
after rising to the ceiling, so install the alarm in the middle
of the ceiling of an ordinary structure house let the alarm
induce every corner.
• Install an alarm in every bedroom.
• Install an alarm in every room where large electrical
appliances are operated (for example portable heaters ).
• If the alarm cannot be installed in the middle of the ceiling
for any reason, position the alarm at least 30cm away from
the wall and corner of the room (see Diagram 5).
• Put smoke alarm at both ends of a bedroom hallway or large
room if the hallway or room is more than 9.1 m (30 ft) long.
• Install smoke alarms on slopped, peaked or cathedral
ceilings between 500 and 1500mm from the highest point
of the ceiling. Smoke alarms in rooms with ceiling slopes
greater than 1m in 8 m horizontally shall be located on the
high side of the room (See Diagram 6)
Diagram 3
- 4 -