background image

 

 

 

 

DISCLAIMER 

FirePro  Systems  makes  no  representations  or  warranties  of  any  kind,  either  express  or  implied, 

statutory  or  otherwise,  including  but  not  limited  to  warranties  of  merchantability,  fitness  for  a 

particular  purpose,  of  title,  or  of  non-infringement  of  third  party  rights,  including  the  intellectual 

property rights of others. 

 

Any information provided by FirePro Systems, relevant to the system engineering of the project is 

indicative and for guidance purposes only. 

 

ompatible  with  the 

equipment used in the system. Furthermore, the responsibility for the preparation and/ or approval 

of a project, subject to its specifications/ technical features and its related documentation, designs 

or  drawings  adherence  (e.g.  design  documentation,  construction,  as-built  drawings,  circuit 

diagram, cable lengths and voltage drop calculations, etc.) to local, national and international laws 

and  regulations,  falls  entirely  within  the  scope  of  the  contractor/  consultant  assigned  for  the 

installation and commissioning. 

 

 

LIMITATION OF LIABILITY 

In  no  event,  regardless  of  cause,  shall  FirePro  Systems  be  liable  for  any  indirect,  special, 

incidental,  punitive  or  consequential  damages  of  any  kind,  whether  arising  under  breach  of 

contract, tort (including negligence), strict liability or otherwise, even if advised of the possibility of 

such damages. 

NOTE 

FirePro  is  constantly  updating  its  products  and  systems  to  the  state  of  the  art  and  therefore 

reserves  the  right  to  make  changes  in  design,  equipment  and  technology.    You  cannot 

therefore base any claims on the data, illustrations or descriptions contained in this literature. 

 

Summary of Contents for FPC-5V2

Page 1: ...FPC 1 P a g e Operation and User Manual FPC 5V2 Panel Fire Protection Controller Issue April 2019 Version 2...

Page 2: ...2 3 Technical Features 2 4 Assembly of unit 4 5 Installation guidelines 6 6 Specifications 7 7 Testing and Commissioning 7 8 FPC5 V2 Module Assembly 9 9 Adaptor plate junction box coupling required 9...

Page 3: ...nections Figure 1 FPC 5V2 module The FirePro fire protection module detects fire by using either a linear heat detector cable or a bimetallic sensor and activates the condensed aerosol fire suppressio...

Page 4: ...erosol generator and it is necessary to replace the battery immediately o When no LED is illuminated either the battery is installed in reverse polarity or it is fully discharged or the unit is set in...

Page 5: ...d Aerosol Generator wires through the FPC 5V2 main body It is important to pass the Condensed Aerosol Generator wires from the same opening of the adaptor plate junction box coupling Figure 6 Step 3 I...

Page 6: ...f the condensed aerosol generator when connected Address this issue first and then proceed to the next step Figure 10 Step 7 Connect the Condensed Aerosol Generator wires electronic PCB Figure 11 Step...

Page 7: ...be installed inside and on the ceiling of the electrical panel enclosure Figure 14 Typical installation The FPC 5V2 module equipped with a bimetallic sensor must be installed in such a way so that the...

Page 8: ...period heat of up to 180o C degrees Table1 Specifications For Testing Commissioning and Simulation purposes the Condensed Aerosol Generator is disconnected from the fire protection module FPC 5V2 and...

Page 9: ...Once the detection line is activated observe whether the LED illuminates Step 6 Cancel the short circuit on the detection line LHD cable or wait for the bimetallic sensor to cool down Step 7 Observe w...

Page 10: ...lectronic PCB CR2 Battery Figure 18 Adaptor plate applicable to Condensed Aerosol Generator series FP 20 Adaptor plate applicable to Condensed Aerosol Generator series FP 40 FP 80 Junction box couplin...

Page 11: ...l 2019 10 P a g e Figure 19 For Box type Condensed Aerosol Generators FP 1200 2000 3000 4200 5700 FP 20 FP 40 80 FP 100 200 500 Figure 19 For Cylindrical type Condensed Aerosol Generators FP 20 40 80...

Page 12: ...FPC 5V2 April 2019 11 P a g e Declarations...

Page 13: ...stbus 70 2288 AB Rijswijk Tel 31 88 998 44 00 www kiwa nl Executed by Kiwa NCP info ncp kiwa nl www kiwafss nl Company FirePro Systems Ltd 8 Faleas Street Agios Athanasios Industrial Area Cy 4041 Lima...

Page 14: ...FP20 T Cylinder No Yes 1 FP20 TH Cylinder Yes No 1 FP40 S Cylinder No Yes 2 FP40 T Cylinder Yes Yes 1 FP80 S Cylinder No Yes 2 FP80 T Cylinder Yes Yes 1 FP100 S Cylinder Yes Yes 1 FP200 S Cylinder Yes...

Page 15: ...s of the supplier manufacturer CEN TR 15276 2 and or evaluation guideline BRL K23003 Point of interest during use or limitation of use The condensed aerosol extinguishing components should not be used...

Page 16: ...d in table 5 Reference to the application instructions Certification mark Fire Class A according EN2 Fire Class B according EN2 Non erasable and non detachable Non flammable Permanent an legible Recom...

Page 17: ...Thermal Activator See 5 12 2 5 12 3 and 7 15 See Kiwa declaration K90415 and K97969 4 4 4 Other methods of ignition device N A 5 Condensed aerosol generator requirements 5 12 Ignition device 5 12 2 E...

Page 18: ...n device Bulb Thermal Activator The bi metal switch and heat cable are mandatory equipped with the FPC 5 ignition device Bi metal switch is tested including an extension cable for bi metal element wit...

Page 19: ...adherence e g design documentation construction as built drawings circuit diagram cable lengths and voltage drop calculations etc to local national and international laws and regulations falls entire...

Page 20: ...FPC 1 P a g e FirePro Systems 8 Faleas Street Agios Athanasios Industrial Area CY 4101 Limassol Cyprus EU Tel 357 25 379999 Fax 357 25 354432 Email mail firepro com www firepro com...

Reviews: