Fan/Engine 

“Spindown” delay time before automatic release. 

Note: Spindown delay only when ignition is ON 

OFF.OFF.OFF.OPT 

 0 Sec = Immediate 

ON.OFF.OFF.OPT   

 5 Sec 

OFF.ON.OFF.OPT   

 10 Sec 

ON.ON.OFF.OPT     

 15 Sec 

OFF.OFF.ON.OPT   

 20 Sec 

ON.OFF.ON.OPT     

 25 Sec 

OFF.ON.ON.OPT     

 30 Sec 

ON.ON.ON.OPT     

 No Automatic Operation 

Installation Notes: 

Ensure that Linear Heat Detectors are suitably mounted for the vehicle vibration levels. 
Front of panel is splash proof but it must be located to prevent excessive moisture or water getting to 
the unit, especially the rear connections.  
Locate to avoid excessive direct solar exposure. 

WARNING!    (And some comm

on sense…..)  

Refer to the installation manual. 

System installation must be verified by a competent technician familiar with regulations governing such 
installations. 
Do not install in Engine, bilge, fuel or gas storage compartments (see RCD and ISO9094). 
In the event of an alarm shutdown the engines and ventilation immediately.  
The cause of the activation must be found and corrected before restarting.  
DO NOT PROCEED TO OVERRIDE UNLESS IT HAS BEEN DETERMINED SAFE TO DO SO. 