10. Position smoke alarm to mounting plate and turn clockwise to

lock into place. For tamper-resist, use long-nosed pliers to
remove thin plastic from notch on smoke alarm edge. Insert
pin into notch on edge of smoke alarm after smoke alarm is
positioned properly in base.

11. Remove arrow tab and close battery door. Smoke alarm may

beep briefly as door is closed.

12. Turn on power at main fuse box or circuit breaker.
13. Test smoke alarm. See “TESTING THE SMOKE ALARM.”

INTERCONNECTING SMOKE ALARMS

This smoke alarm may be interconnected with as many as 11
other Firex model FADC, AD, ADC, PAD or FX1218 smoke
alarms, and as many as 6 Firex model ADH heat alarms for a
total of not more than 18 interconnected devices. DO NOT con-
nect to any other type or model smoke alarm.

Connect smoke alarms to a single AC branch circuit. If local codes
do not permit, be sure the neutral wire is common to both phases.

LED INDICATOR(S)

Model FADC features one combined LED indicator. The following
section explains what condition the LED indicator is describing:

• Constant GREEN on

- AC power is present

• GREEN is off

- AC power is NOT present

• RED blinks once a minute

- testing for presence of good 

battery

• RED blinks once a second

- smoke alarm senses smoke 

and simultaneously sounds 
an alarm

• RED blinks once every 10

- smoke alarm is quieting an

seconds

unwanted alarm (Models 
ADC and FADC only)

• RED is off and detector in alarm - another smoke alarm in the

(interconnected systems only)

network has sensed smoke 
and is signaling this alarm.

Item 4718 only

• RED blinks 3 times every minute - indicates this unit initiated an alarm

in an interconnected system
(press the test button to reset).

• RED blinks 4 times every minute - indicates weak or improperly

preceded by an audible chirp

connected battery.

WHITE

WHITE

WHITE

YELLOW

YELLOW

BLACK

BLACK

BLACK

TO GROUND

TO 120 VAC

Insert pin here

7

Remove pin from here

110-1082B  12/12/06  4:01 PM  Page 7

Summary of Contents for FADC

Page 1: ...e previous alarm sound which continually beeped Test button checks smoke alarm operation and activates False Alarm Control feature which quiets unwanted alarms for up to 15 minutes Item 4718 features a latching LED which blinks the initiating alarm s red LED 3 times each minute until manually reset Item 4718 has a ramp up test horn feature which emits 2 reduced volume beeps before reaching the ful...

Page 2: ...on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed Interconnected ...

Page 3: ... in each sleeping room Chapter 2 also reads as follows 2 2 2 1 In new construction where more than one smoke detector is required by 2 2 1 they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound The NFPA 1993 Edition Appendix A further states The required number of smoke detectors may not provide reliable early warnin...

Page 4: ... Story Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleep ing area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Two Story or Split Level Home Install a smoke alarm on the ceiling or wal...

Page 5: ... highest point measured horizontally Install a smoke alarm in lived in attics or attics which house electri cal equipment like furnaces air conditioners or heaters DO NOT install smoke alarm Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas In areas with high humidity l...

Page 6: ... plate To later engage tamper resist feature twist out and set aside one of the pins molded into the plate Both pins are exactly the same 2 Align recessed slots on plate with mounting holes of a 4 inch octa gon or single gang junction box 3 Gently pull household wires through center hole of plate 4 Secure plate to junction box using mounting screws 5 With a small wire connector connect white wire ...

Page 7: ...re the neutral wire is common to both phases LED INDICATOR S Model FADC features one combined LED indicator The following section explains what condition the LED indicator is describing Constant GREEN on AC power is present GREEN is off AC power is NOT present RED blinks once a minute testing for presence of good battery RED blinks once a second smoke alarm senses smoke and simultaneously sounds a...

Page 8: ... ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days FIELD TESTING IMPORTANT NOTICE When testing is required in the field by local inspectors or other par ties it should be done using only the Smoke Detector Sensitivity Analyzer model 501 1 manufactured by Gemini Scientific Corporation Fo...

Page 9: ...ute even though the smoke alarm is receiving AC power On item 4718 the red LED will also blink 4 times every minute after each low battery chirp Use only the following batteries as replacements in this smoke alarm Eveready 522 or 1222 Duracell MN 1604 or Ultralife U9VL J WARNING DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECIFIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn off pow...

Page 10: ...moke alarm and explain what the sound means Determine TWO exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alternate exit if the door is hot INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Determine a safe meeting place ...

Page 11: ... only Be sure red LED is extinguished after replacing battery Smoke alarm sounds 1 Hire an electrician to unwanted alarms inter move smoke alarm to mittently or when a new location See residents are cooking SMOKE ALARM taking showers etc PLACEMENT 2 Clean smoke alarm See Cleaning in the MAINTENANCE AND CLEANING section Interconnected smoke 1 Press and hold test alarms do not sound when button for ...

Page 12: ...ntrols Americas smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas This warranty does not cover damage resulting from acci dent misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPART...

Reviews: