Page 20
3.Plug in and turn on the desired 120 Volt AC,
single phase, 60Hz electrical loads. It is
better to attach the item with largest load first.
Connecting a generator to your electric utility
company’s power lines or to another power
source may be against the law. In addition this
action, if done incorrectly, could damage your
generator and appliances and could cause
serious injury or even death to you or a utility
worker who may be working on nearby power
lines. If you plan to run a portable electric
generator during an outage, please notify your
electric utility company immediately and
remember to plug your appliances directly into
the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company
8. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Connecting Electrical Loads
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
on position.
This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated
via the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
CAUTION
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
power lines. You are responsible for ensuring
that your generator’s electricity does not feed
back into the electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility
company or a qualified electrician. Connections
must isolate generator power from utility
power and must comply with all applicable laws
and codes.
Economy Control Switch
The Economy Control switch can be activated in
order to minimize fuel consumption and noise
while operating the unit during times of reduced
electrical output, allowing the engine speed to
idle during periods of non-use. The engine speed
returns to normal when an electrical load is
connected. When the economy switch is off, the
engine runs at normal speed continuously.
WARNING
For periods of high electrical load or momentary
fluctuations, the Economy Control Switch should
be turned OFF.
While the Engine Switch is in the “
RUN
” (
I
) position
and the battery power restore switch has been
pressed for about 3 seconds, the remote module is
active and waiting for signal. This function requires
electrical current which is consuming the battery.
Remote Control Power Consumption
THIS GENERATOR WILL AUTOMATICALLY
DISCONNECT THE BATTERY AFTER 12 HOURS
TO AVOID BATTERY DRAINAGE, IF THE
GENERATOR IS NOT RUNNING AND THE ENGINE
SWITCH IS LEFT IN “RUN” (I) POSITION.
YOU MUST GO THROUGH STARTING PROCEDURE
TO RESUME RUNNING THE UNIT AGAIN.
English Customer Service: 1-844-347-6261
Summary of Contents for etrailer W02983
Page 34: ...Page 31 171cc Engine Parts Diagram English Customer Service 1 844 347 6261...
Page 41: ...P N 329745452 Rev 01...
Page 75: ...31 SPE175ER 171cc Motor Diagrama De Las Piezas Espa ol Servicio al Cliente 1 844 347 6261...
Page 116: ...31 SPE 175ER 171cc Moteur Sch ma Des Pi ces Fran ais Service Clients 1 844 3476261...