background image

DANGER

Long Term Storage

It is important to prevent gum deposits from forming
in essential fuel system parts such as the carburetor,
fuel  hoses  or  tank  during  storage.  Also,  experience
indicates  that  alcohol-blended  fuels  (called  gasohol,
ethanol or methanol) can attract moisture, which leads
to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine
while in storage.
When the generator set is not being operated, or
is being stored for more than one month, follow
these instructions to avoid engine problems:
1-

ADD

 a properly formulated commercially 

FUEL

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate
treated  fuel  into  fuel  lines  and  carburetor  before

3- After engine cools down, remove all gasoline
from the fuel tank. Use a commercially available,
non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.

4-

FUEL STARVATION:

  Start and run the generator

until it stops  from lack of fuel. This will dry out all
remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon
of engine oil through the spark plug hole, then pull
the recoil starter several times to distribute the oil for
lubricating  the  cylinder.  Reattach  the  spark  plug.
Pull  recoil  slowly  until  resistance  is  felt.  This  will
close  the  valves  so  moisture  cannot  enter  engine
cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning
and storage.

6-Change oil with recommended grade oil.

Any  damages  or  hazards  caused  by  using
improper  fuel,  improperly  stored  fuel,  and/
or improperly formulated stabilizers, are not
covered by manufacturer's warranty.

8-Keep the engine switch and fuel valve on “OFF”
position.
9-Cover the unit and store in a clean, dry place
out of direct sunlight. 

NEVER USE WATER TO

CLEAN GENERATOR.

NOTE:

We recommend always using a fuel stabilizer.

A FUEL STABLIZER

 will minimize the formula-

tion of fuel gum deposits during storage, the
fuel stabilizer can be added to the gasoline in
the fuel tank, or into the gasoline in a storage
container.

If  it  is  not  practical  to  empty  the  fuel  tank  and
the  unit  is  to  be  stored  for  some  time,  use  a
commercially available 

FUEL STABILIZER

 added

to the gasoline to increase the life of the gasoline.
Run  the  unit  for  5-10  minutes,  turn  off  the  fuel
valve  and  allow  to  run  until  engine  stops  from
lack of fuel (

FUEL STARVATION

).

Do not store gasoline from one season to
another season.

Summary of Contents for P03501

Page 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Page 2: ...Table of Contents Connecting to a Building s Electrical Trouble Shooting 24 Parts Diagram and Parts List 25 Generator Parts Diagram 25 Engine Parts Diagram 26 Parts List 27 Service Information 29 22...

Page 3: ...e that the procedure work method or operating technique that you choose does not render the generator unsafe DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which if not avoi...

Page 4: ...SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD WARNING WARNING...

Page 5: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Page 6: ...could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removi...

Page 7: ...et weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Page 8: ...s or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of...

Page 9: ...y Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operat...

Page 10: ...erator requires some assembly prior to usage Install the Wheel Kit F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the axle pin A thro...

Page 11: ...r 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 8 0 Flat Free Wheel 11 Oil Filler Cap 12 Outlet Cover 13 Control Panel 14 Handle We are always working to impr...

Page 12: ...30A RV NEMA TT 30R Total power drawn from all receptacles must not exceed the name plate rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 A Digital display B AC voltage indica...

Page 13: ...tive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4450 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPORT...

Page 14: ...the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shif...

Page 15: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Page 16: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Page 17: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 18: ...tion 9 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator to stablize WARNING When starting engine pull cord slowly until resistance is felt an...

Page 19: ...ine speed adjusted at the factory for correct output Readjusting will void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more recept...

Page 20: ...below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Author...

Page 21: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Page 22: ...ain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a...

Page 23: ...ainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean wi...

Page 24: ...rator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and...

Page 25: ...out one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slowly unti...

Page 26: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Page 27: ...PARTS DIAGRAM AND PARTS LIST P03501 PARTS DIAGRAM...

Page 28: ...FIRMAN 208cc Engine Parts Diagram...

Page 29: ...336413502 336413503 336413508 336413509 Fuel Valve Guard Muff Frame Axle Pin Wheel Cotter Pin Rubber Support Nut M8 Bolt M8 16 Support Leg Bolt M6 25 IsolatorA Isolator B Grommet Screw M5 14 Control...

Page 30: ...587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 336423505 54 55 56 57 58 5...

Reviews: