Page 14
Altitude main jet 1
Altitude main jet 2
208cc
335717002
335717003
Altitude
3000-6000Feet
6000-8000Feet
OPEN
Operation
using
the
alternative
main
jet
at
elevations
lower
than
the
recommended
minimum altitude
can
damage
the
engine
.
For
operation
at lower
elevations
,
the
standard
main
jet
must
be used
.
Operating
t h e
e n g i n e
w i t h
t h e
w r o n g
e n g i n e
configuration
at
a
given
altitude
may
increase its
emissions
and
decrease
fuel
efficiency
and performance
.
WARNING
Grounding
The National Electric Code requires your generator
must be properly connected to an appropriate
ground to help prevent electric shock.
Failure to properly ground the
generator can result in electric
shock.
WARNING
A ground terminal connected to the frame of
the generator has been provided on the control
panel. For remote grounding, connect of a
length of heavy gauge (12 AWG minimum)
copper wire between the generator ground
terminal and a copper rod driven into the
ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.
THERE IS A PERMANENT CONDUCTOR BETWEEN
THE GENERATOR (STATOR WINDING) AND THE
FRAME.
Use approved transfer equipment to prevent
backfeed by isolating generator from electric
utility workers.
When using generator for backup power, notify
utility company.
Use a ground fault circuit interrupter (GFCI) in
any damp or highly conductive area, such as
metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords
which are worn,frayed, bare or otherwise
damaged.
DO NOT operate generator in the rain or wet
weather.
DO NOT handle generator or electrical cords
while standing in water, while barefoot, or
while hands or feet are wet.
DO NOT allow unqualified persons or children
to operate or service generator.
Connecting to a Building's Electrical System
Connections for standby power to a building's
electrical system must be made by a qualified
electrician. The connection must isolate the
generator power from utility power or other
alternative power sources and must comply
with all applicable laws and electrical codes.
WARNING
Generator voltage could cause
electrical shock or burn resulting
in death or serious injury.
•
•
•
•
•
•
•
•
The
part
number
and
recommended
minimum
altitude for
the
application
of
the
high
altitude
carburetor
main jet
is
listed
in
the
table
below
.
main jet
and
installation
instructions
can be
obtained
by contacting
Customer
Support
.
Installation
instructions are
also
available
in
the
Technical
Bulletin
area
of
the FIRMAN
internet
site
.