background image

Page 05

WARNING

Unintentional sparking 
could cause fire or 
electric shock resulting 
in death or serious 
injury.

WHEN ADJUSTING OR MAKING REPAIRS TO 
YOUR GENERATOR

Disconnect the spark plug wire from the 
spark plug and place the wire where it cannot 
contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT

 check for spark with spark plug 

removed.

WARNING

NEVER

 operate generator without protective 

housing or covers.

DO NOT

 wear loose clothing, jewelry or 

anything that could be caught in the starter 
or other rotating parts.
Tie up long hair and remove jewelry.


DO NOT exceed the generator’s wattage
amperage capacity. 
Start generator and let engine stabilize 
before connecting electrical loads.

CAUTION

Exceeding generators wattage/amperage capacity 
could damage generator and/or electrical devices 
connected to it.

Connect electrical loads in OFF position, 
then turn ON for operation.
Turn electrical loads OFF and disconnect 
from generator before stopping generator.


DO NOT

 use generator with electrical cords 

which are worn, frayed, bare or otherwise 
damaged.

DO NOT

 operate generator in the rain or 

wet weather.

DO NOT

 handle generator or electrical 

cords while standing in water, while 
barefoot, or while hands or feet are wet.

DO NOT

 allow unqualified persons or 

children to operate or service generator.

WARNING

Exhaust heat/gases could ignite combustibles, 
structures or damage fuel tank causing a fire, 
resulting in death or serious injury.
Contact with muffler area could cause burns 
resulting in serious injury.

DO NOT

 touch hot parts and 

AVOID

 hot 

exhaust gases.
Allow equipment to cool before touching.
It is a violation of California Public Resource 
Code, Section 4442, to use or operate the 
engine on any forest-covered, brush-covered, 
or grass-covered land unless the exhaust 
system is equipped with a spark arrester, as 
defined in Section 4442, maintained in 
effective working order. Other states or 
federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, 
retailer, or dealer to obtain a spark arrester 
designed for the exhaust system installed on 
this engine.
Replacement parts must be the same and 
installed in the same position as the original 
parts.

When using generator for backup power, 
notify utility company.
Use a ground fault circuit interrupter (GFCI) 
in any damp or highly conductive area, 
such as metal decking or steel work.

DO NOT

 touch bare wires or receptacles.


English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

NOTICE

Summary of Contents for P06701

Page 1: ...GASOLINE PORTABLE GENERATOR P N 367745450 Rev 01 Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P06701 Rev Level 00 OPERATOR S MANUAL...

Page 2: ...rotection 15 Starting the Generator 16 Connecting Electrical Loads 17 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Introduction Connecting to a Building s Electrical Mainten...

Page 3: ...ginal instructions for future reference Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and...

Page 4: ...Page 02 English Customer Service 1 844 FIRMAN1 SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...r serious injury WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tan...

Page 7: ...DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING...

Page 8: ...s or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of...

Page 9: ...or to usage If problems arise when assembling the generator call 1 844 347 6261 F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the ax...

Page 10: ...Air Filter 7 389cc FIRMAN OHV Engine 8 Recoil Starter 9 10 0 25 4cm Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel 13 Handle 14 Data Decal We are always working to improve our pro...

Page 11: ...Fault Circuit Interrupter conforms to UL 943 and NEC requirements This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity...

Page 12: ...stop the flow of electricity making the lamp shut off The GFCI s indicator light comes off RESET TEST TEST MONTHLY FOLLOW DIRECTIONS RESET BUTTON Receptacle Outlet LED Indicator Light TEST BUTTON Out...

Page 13: ...d Engine Oil Section Total Harmonic Distortion THD Standard AC Grounding System Neutral Bonded To Frame This generator is rated in accordance with ANSI PGMA G300 2018 AN IMPORTANT MESSAGE ABOUT TEMPER...

Page 14: ...evel may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil H DRAIN PLUG L 5 Replace oil fill cap dipstick and fully tighten 6 Oil level should be checke...

Page 15: ...tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarette or smoke when filling the fuel tank 1 Clean area around fuel fill cap remove cap 2 Slowly add unlead...

Page 16: ...l is bonded to the generator frame There may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspec...

Page 17: ...rom the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the...

Page 18: ...rting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until resistance is felt and th...

Page 19: ...applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical...

Page 20: ...n a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Overloading a generator in exc...

Page 21: ...hould clean or replace the spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Bef...

Page 22: ...Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine change oil...

Page 23: ...avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspe...

Page 24: ...dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can enter the generator t...

Page 25: ...ank Use a commercially available non conductive vacuum siphon shutdown Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke 4 FUEL STARVATION Start and...

Page 26: ...sion 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tan...

Page 27: ...Page 25 PARTS DIAGRAM AND PARTS LIST P06701 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 28: ...Page 26 English Customer Service 1 844 FIRMAN1 FIRMAN 389cc Engine Parts Diagram...

Page 29: ...8 Pin Shaft Cover Handle Pin Handle Bracket Handle Handle Flange Bolt M8 50 Nut M8 Flange Bolt M8 16 Support Leg Assembly Support Leg Rubber Support 336713561 336723555 357713535 357713514 357713536 3...

Page 30: ...ovorner Gear Rod Connecting Pin Piston Clip Piston Pin Ring Set Oil Ring The Second Ring The First Piston Gasket Cylinder Head Locating Pins 12 20 Air Guide Lower Head Subassembly Cylinder NO Part Num...

Page 31: ...Page 29 English Customer Service 1 844 FIRMAN1 Wiring Diagram...

Page 32: ...by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a w...

Page 33: ...rranty excludes cosmetic defects such as paint decals etc wear items accessory parts failures due to acts of God and other force majeure events beyond the manufacturer s control problems caused by par...

Page 34: ...ately caused by a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions...

Page 35: ...g Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses a...

Page 36: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 PEORIA AZ 85381 1 844 347 6261 WWW FI...

Page 37: ...INA MANUAL DEL OPERADOR N MERO DE MODELO P06701 Rev Nivel 00 Registre la informaci n del producto como referencia cuando solicite partes u obtenga la cobertura de la garant a N MERO DE SERIE FECHA DE...

Page 38: ...n de Cargas El ctricas 17 Parada del Motor 17 Desconexi n Por Nivel de Aceite Bajo 18 No Sobrecargue El Generador 18 Solucion de Problemas 24 Diagrama de Las Piezas Y Lista de Piezas 25 Diagrama de L...

Page 39: ...encias en este manual y las etiquetas y pegatinas adheridas en la unidad no incluyen todas las posibilidades Si usted sigue un procedimiento un m todo de trabajo o una t cnica de funcionamiento que el...

Page 40: ...ciones del fabricante Los detectores de humo no pueden detectar el gas de mon xido de carbono NO haga funcionar este producto dentro de casas garajes s tanos espacios de acceso cobertizos u otros espa...

Page 41: ...Direccionar el tubo de escape lejos de espacios ocupados USO INCORRECTO No utilizar en ninguno de los lugares siguientes Cerca de una puerta ventana o conducto de ventilaci n Garaje S tano S tano de p...

Page 42: ...Si se vierte combustible espere hasta que se evapore antes de poner el motor en marcha Mantenga el combustible lejos de chispas llamas abiertas luces piloto calor y otras fuentes de ignici n Revise fr...

Page 43: ...das el ctricas que est n gastadas peladas o da adas de alg n modo NO hacer funcionar el generador bajo la lluvia o con un clima h medo NO manipular el generador o cables el ctricos si se est encima de...

Page 44: ...e potencia o electrodom sticos m dicos Informe a su proveedor el ctrico inmediatamente si usted o alguien en su hogar depende de un equipo el ctrico para vivir Informe a su proveedor el ctrico inmedia...

Page 45: ...F H K 1 Antes de a adir las ruedas gire el generador hacia un lado 2 Deslice el sujetador del eje A a trav s de la rueda 3 Deslice el sujetador del eje A a trav s del punto de montaje en el marco y la...

Page 46: ...o de aire 7 Motor FIRMAN OHV 389cc 8 Interruptor de encendido de retroceso 9 Rueda libre y plana 10 0 25 4cm 10 Tap n del dep sito de aceite 11 Cubierta de salida 12 Panel de control 13 Manivela 14 Et...

Page 47: ...mps de corriente podr an recibirse en el recept culo Sin embargo la potencia total deber a mantenerse seg n la que se indica en la placa de identificaci n Ground Fault Circuit Interruptor cumple con U...

Page 48: ...rueba debe encenderse 3 Presione el bot n de Test ubicado al frente del recept culo para activar el dispositivo 4 Esto debe detener el flujo de electricidad haciendo que la l mpara se apague La luz in...

Page 49: ...Cepillo Por Retroceso 11 Spanish Servicio al Cliente 1 844 FIRMAN1 389cc 8 0 Gallon 37 2 oz 1 1L Est ndar Sistema de puesta a tierra de CA Neutro Conectado Al Bastidor Este generador est clasificado...

Page 50: ...ber a ser revisado antes de cada uso o almenos cada 8 horas de funcionamiento Realice un buen mantenimiento del nivel de aceite H L 12 Spanish Servicio al Cliente 1 844 FIRMAN1 Recomendamos usar el ac...

Page 51: ...ible L nea de llenado 13 Spanish Servicio al Cliente 1 844 FIRMAN1 AVISO dep sitos de goma en las partes del sistema de combustible tales como el carburador la manguera de combustible o el tanque dura...

Page 52: ...os terminales de tierra en los recept culos de salida de CA La tierra del sistema est conectada al cable neutro de CA El neutro est unido al bastidor del generador Puede haber regulaciones federales o...

Page 53: ...icie estable y nivelada Protecci n contra Sobrecargas PELIGRO POR GAS T XICO No bloquee el conducto de ventilaci n del generador con papel u otro material Inclinarlo podr a causar derramamiento de com...

Page 54: ...rador es estabilice 4 Ponga la v lvula del carburante en posici n ON l 7 Tire lentamente de la cuerda de arranque hasta que note resistencia luego tira r pidamente ADVERTENCIA 16 Spanish Servicio al C...

Page 55: ...la unidad se haya enfriado 2 Muevalav lvuladecarburamtehacialaposici n OFF O 3 Pulse el interruptor del motor a la posici n OFF O Deje que funcione el motor hasta que la falta de combustible lo pare E...

Page 56: ...3 Contacte con un servicio de Distribuci n autorizado FIRMAN 4 NO utilice el motor hasta que el nivel de aceite sea correcto Para prolongar la vida de su generador y los dispositivos conectados siga...

Page 57: ...haya fugas Volver a ajustar o reemplazar la junta si es necesario Revisar Reemplazar si es necesario Comprobar que no haya grietas u otros da os en la manguera de carburante Reemplazar si es necesario...

Page 58: ...e el aceite cada 25 horas Por favor utilice un contenedor para vaciar el aceite usado para proteger el medio ambiente b Vuelva a instalar el tap n de drenaje y a llenar el motor con aceite hasta que a...

Page 59: ...rante a Quite el c liz del filtro y tire el agua y la suciedad b Limpie las rejillas y el c liz del carburante con gasolina c Ajuste bien el c liz al cuerpo principal asegur ndose que se evita cualqui...

Page 60: ...d n para limpiar el generador El agua podr a entrar en el generador a trav s de las ranuras de refrigeraci n y da ar las bobinas del generador Utilice un pa o h medo para limpiar las superficies exter...

Page 61: ...combustible minimizar la formulaci n de dep sitos de goma de combustible durante el almacenamiento el estabilizador de combustible se puede agregar a la gasolina en el tanque de combustible o en la g...

Page 62: ...as defectuoso 4 El dispositivo est mal conectado 1 Reinicie el cortacircuitos 2 Contacte con instalaci n de servicio autorizado 3 Revise y repare 4 Con ctelo a otro dispositivo que est en buenas condi...

Page 63: ...DIAGRAMA DE LAS PIEZAS Y LISTA DE PIEZAS P6701 DIAGRAMA DE LAS PIEZAS 25 Spanish Servicio al Cliente 1 844 FIRMAN1...

Page 64: ...26 Spanish Servicio al Cliente 1 844 FIRMAN1 FIRMAN 389cc Motor DIAGRAMA DE LAS PIEZAS...

Page 65: ...13529 336713546 336713547 393713018 336713551 380713510 336713540 357713525 357713562 357718300 357713531 357713532 357713533 357713531 336713564 336713565 329713608 357713539 336713568 367718300 3367...

Page 66: ...undo Anillo el primero Pist n Culata Junta Pernos de ubicaci n 12 20 Gu a de aire inferior 1 1 1 1 1 3 1 6 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 3 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 55...

Page 67: ...Diagrama de Cableado 29 Spanish Servicio al Cliente 1 844 FIRMAN1...

Page 68: ...no cubre las reparaciones y equipos siguientes Esta garant a s lo se aplica al comprador original y no es transferible Garant a Limitada de Tres 3 A os FIRMAN Desgaste Normal 30 Spanish Servicio al C...

Page 69: ...seguir calculando en funci n de la fecha de compra de la unidad original Esta garant a le otorga ciertos derechos legales que pueden variar de estado a estado Su estado puede que tambi n tenga otros d...

Page 70: ...omprador final y a cada subsecuente comprador que el motor est Dise ado fabricado y equipado para cumplir con todas las regulaciones aplicables asoptadas por la Junta de Recursos de Aire y EPA Agencia...

Page 71: ...s internas 3 Ensamblaje del silenciador catal tico incluyendo Colector del escape Convertidor catal tico Junta del silenciador V lvula de tensi n 4 Sistema de inducci n por aire incluyendo Tuber a de...

Page 72: ...l uso no autorizado sin una autorizaci n por escrito S GUENOS EN LAS REDES SOCIALES USO PARA TENER LA OPORTUNIDAD DE GANAR UN SWAG DE FIRMAN TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 PEOR...

Reviews: