English Customer Service: 1-844-FIRMAN1
19
OPERATION
CO Alert
Carbon Monoxide (CO) Shutdown System
CO Alert automatically shuts down the engine when harmful levels of carbon monoxide
accumulate around the generator or a CO Alert fault occurs. After shutdown, the CO Alert
indicator light will blink for at least five minutes per the chart below.
CO Alert DOES NOT replace carbon monoxide alarms.
Install battery-powered carbon monoxide alarm(s) in your home. Don’t run generator in enclosed
areas.
Color
Description
Red
Yellow
CO Alert fault occured*.
See FIRMAN authorized service dealer.
*
Yellow light will blink for five seconds at the startup of generator to show CO ALERT is functioning
properly.
TM
Carbon monoxide accumulated around generator. Prior
to restart move generator to an open, outdoor area
20 ft. (6 m) from occupied spaces with exhaust pointed
away. Air out premises (open windows and doors) before
reoccupying property. Automatic shutoff is an indication
generator was improperly located.
If you start to feel sick, dizzy, weak, or your homes carbon
monoxide alarm sounds while using this product, get to
fresh air right away. Call emergency services. You may
have carbon monoxide poisoning.
•• ••
•••
•
•
5. Stopping the generator
1. Turn off and remove all electrical loads.
Never stop the generator with electrical devices plugged in and turned on.
Never stop the engine by moving the choke to the start position.
Let the generator run at no-load for one minute to stabilize internal temperatures of the engine
and generator.
Summary of Contents for P08008
Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS ...
Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS ...
Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS ...
Page 31: ...PARTS DIAGRAM AND PART LIST P08008 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30 ...
Page 32: ...439cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 31 ...