P/N:380745462 Rev:00

GASOLINE  PORTABLE  GENERATOR

Record product information to reference when ordering parts or 
obtaining warranty coverage.

MODEL

 

NUMBER

P08013

Rev Level:00

OPERATOR’S  MANUAL

Summary of Contents for P08013

Page 1: ...P N 380745462 Rev 00 GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P08013 Rev Level 00 OPERATOR S MANUAL...

Page 2: ...pport This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for suppl...

Page 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 4: ...ble generator is designed to be used only with FIRMAN authorized parts The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacl...

Page 5: ...ED Extension cords running directly into the home increase your risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is used to power indoor item...

Page 6: ...1 Fuel Gauge 2 8 0 Gallon 30L Capacity Fuel Tank 3 Fuel Cap 5 Fuel Valve 6 Air Filter 7 439cc FIRMAN OHV Engine 8 Recoil Starter 9 10 0 25 4cm Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Cont...

Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 10: ...ectrician or authority having jurisdiction for local grounding requirements 3 Battery Switch Power the electric starter 4 Remote Start Indicator Light The light will light or flash depending on the st...

Page 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Page 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact FIRMAN custom...

Page 15: ...ative main jet and installation instructions can be obtained by contacting customer service NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Page 16: ...2 Move portable generator outdoors to safe operating location at least 20 ft 6 m from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the gen...

Page 17: ...apidly 10 Do not over choke As soon as engine starts and warms up move the choke lever to the RUN position 11 Push and release the START button on the remote control The generator will turn over for 3...

Page 18: ...r service If GFCI trips while in use reset and test the outlet Electric cords laying on the ground with worn insulation may trip the GFCI only use cords in good condition RESET TEST TEST MONTHLY FOLLO...

Page 19: ...th the largest load first 5 Allow the engine to stabilize 6 Plug in and turn on the next item 7 Allow the engine to stabilize 8 Repeat steps 5 6 for each additional item Surge Protection There is a re...

Page 20: ...show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior to restart move generator to an open outdoor area 20 ft 6 m from occupied spaces with exhaust pointed away...

Page 21: ...15 seconds as it goes through a cool down cycle before shutting off STOP 3 Flip the engine switch to OFF O position 4 Flip the battery switch on OFF O position STOP If a cover is used do not install...

Page 22: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Page 23: ...olonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REAC...

Page 24: ...a clean cloth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easi...

Page 25: ...ARNING Contact with muffler area could cause burns resulting in serious injury Do not tough hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the engine on...

Page 26: ...all exterior surfaces 25 Run the generator at least 30 minutes every month Maintenance Storage Inspect Muffler and Spark Arrester 1 Inspect the muffler for cracks corrosion or other damage 2 Remove t...

Page 27: ...If the battery is not able to start the engine the battery must be connected to a standard automotive style battery charger for re charging before it can be used Battery Charging 26 Maintenance Stora...

Page 28: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 29: ...soline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility Engine la...

Page 30: ...Cylinder 4 Stroke OHV Air Cooled 439cc Breakless Ignition Type Flywheel Magneto Unleaded Automotive Gasoline 8 U S Gallons 30L 37 2 oz 1 1L Counter Clockwise Facing P T O Float Brushed Polyurethane Ty...

Page 31: ...PARTS DIAGRAM AND PART LIST P08013 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 30...

Page 32: ...439cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 31...

Page 33: ...r 8 2 17 0 8 Cotter Pin Handle Cover Handle Axle Pin Handle Bracket Handle Handle Assy Stuffy 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 2 1 1 2 4 2 2 1 1 1 2 1 1 4 1 7 1 2 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 1 NO Par...

Page 34: ...x Nut M4 Circuit Breaker Amp 33A Rectifier Bridge Charge Module Control Module Nut M3 Multi Meter Switch Remote Holder Remote Control Engine Switch Switch Pilot Lamp Outlet Cover TT 30R Outlet Cover L...

Page 35: ...cond Piston 3 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 5 1 1 1 2 7 2 2 1 1 1 2 1 1 2 1 2 1 1 2 2 1 4 1 1 1 1 1 1 1 1 2 1 1 NO Part Number Description Qty 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67...

Page 36: ...6718314 357723554 375418307 375418303 375418304 375418305 380423504 Choke Connector Spring Step Moter Holder Step Moter Bolt M4 8 Step Moter Cover Air Cleaner Assy Elbow Air Cleaner Seal Clapboard Nut...

Page 37: ...English Customer Service 1 844 FIRMAN1 36 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 38: ...pt of your Warranty Registration Card and a copy of your sales receipt from one of FIRMAN s retail locations as proof of purchase Please submit your warranty registration and your proof of purchase wi...

Page 39: ...8 Installation Use and Maintenance This warranty will not apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generato...

Page 40: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your small off road engine and engine powered equipment is warr...

Page 41: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 42: ...0 All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8644 W Ludlow Dr Peoria AZ 85381 1 844 347 6261 www firman...