1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: 
1a. This device may not cause harmful interference. 
1b. This device must accept any interference received, including interference that may cause 
undesired operation. 
2. Changes or modifications not expressly approved by the party responsible for compliance 
could void the user’s authority to operate the equipment. 

NOTE:

 The FIRMAN W01785 inverter generator has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Supplier’s Declaration of Conformity

47 CFR § 2.1077 Compliance Information

FIRMAN W01785 INVERTER GENERATOR

Firman Power Equipment

8716 W. Ludlow Dr. Suite #6

Peoria, AZ 85381

Telephone: 1-844-347-6261

www.firmanpowerequipment.com

Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver 
is connected.
Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications to equipment not expressly approved by FIRMAN could void the user’s 
authority to operate the equipment.

••

FCC/IC Compliance Statement

Summary of Contents for W01785

Page 1: ...P N 317745454 Rev 00 OPERATOR S MANUAL PORTABLE INVERTER GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER W01785 Rev Level 00...

Page 2: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Page 3: ...f the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lightin...

Page 4: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 5: ...rts FIRMAN There may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency...

Page 6: ...n cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the home and assumes that risk DANGER Engine...

Page 7: ...s valve to the On position to supply air to the tank 3 Fuel Cap 4 Control Panel 5 Recoil Starter 6 Muffler Spark Arrester 7 Spark Plug Access Cover 8 Maintenance Cover Oil filler and air filter access...

Page 8: ...06 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...

Page 9: ...07 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...

Page 10: ...08 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...

Page 11: ...cles must not exceed the data decal rating 5 120V 20A NEMA 5 20R Not GFCI protected A maximum of 14 2 Amps current may be drawn from this duplex receptacle 2 120V 30A Receptacle NEMA L5 30R A maximum...

Page 12: ...osition to turn off the generator 12 DC 5V A USB Outlet 2 1 13 Fuel Valve Knob 15 Circuit Breakers The receptacles are protected by AC circuit protectors If the generator is overloaded or an external...

Page 13: ...nclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off If you...

Page 14: ...any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator indoors to protect it from the weather Do...

Page 15: ...d NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage due to operation with no oil will void your warranty Degrees...

Page 16: ...ctivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman customer service Low...

Page 17: ...there may be a decrease in power Maximum wattage and current are subject to and limited by such factors as ambient temperature altitude engine conditions etc Operation at High Altitude At altitudes o...

Page 18: ...Move portable generator outdoors to safe operating location at least 20 ft 6m from any occupied spaces 16 OPERATION 3 Disconnect all electrical loads from the generator Never start or stop the genera...

Page 19: ...t fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 8 Pull the starter cord slowly until resistance is felt and then p...

Page 20: ...he closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the first item It is best to attach the it...

Page 21: ...t 6 m from occupied spaces with exhaust pointed away Air out premises open windows and doors before reoccupying property Automatic shutoff is an indication generator was improperly located If you star...

Page 22: ...or one minute to stabilize internal temperatures of the engine and generator 2 Flip the engine switch to OFF O position If a cover is used do not install until unit has cooled 3 Turn the fuel valve to...

Page 23: ...tabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 Plug in and turn on the next item 6 Allow the engine to stabil...

Page 24: ...r New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable experienced owner or by authorized ser...

Page 25: ...imals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS NOTICE We recommend using FIRMAN SAE 10W 30...

Page 26: ...spark plug will help your engine start easier and run at peak performance a Remove the maintenance cover b Remove the spark plug boot c Remove spark plug using provided wrench 24 d Reinstall clean or...

Page 27: ...with muffler area could cause burns resulting in serious injury Do not touch hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any forest cov...

Page 28: ...Maintenance Storage Inspect Muffler and Spark Arrester 1 Remove the maintenance cover and inspect the muffler for cracks corrosion or other damage 2 Loosen the spark arrester screws remove the spark...

Page 29: ...from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained turn fuel valve to on position Start and r...

Page 30: ...cessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to prop...

Page 31: ...eaded Automotive Gasoline 0 9Gal 3 4L 12 9oz 0 38L Counter Clockwise Facing P T O Float Polyurethane Type Yes 2100 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Recoil AC Grounding Sy...

Page 32: ...PARTS DIAGRAM AND PART LIST W01785 PARTS DIAGRAM 30 English Customer Service 1 844 FIRMAN1...

Page 33: ...80cc ENGINE PARTS DIAGRAM 31 English Customer Service 1 844 FIRMAN1...

Page 34: ...l Nozzle Screw M6 15 Isolator Bolt M6 15 Isolator Nut M6 Nut M6 Bolt M6 12 Base Mounting Base Mounting Base Assy Passageway Air Cleaner Wire Clip Screw M5 20 Bridge Rectifier Ground Wire Control Unit...

Page 35: ...1 1 3 1 1 1 1 1 1 4 1 2 2 2 1 1 1 2 1 2 2 2 1 1 1 1 2 1 1 1 2 1 1 1 2 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 1 1 1 1 1 1 Bolt M6 12 Guide rope Corrugated Pipe Recoil Starter Knob Handle...

Page 36: ...34 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram English Customer Service 1 844 FIRMAN1...

Page 37: ...arges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the original purchaser and is not transferable 3 yea...

Page 38: ...t Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are here for you 36 Installation Use and Mai...

Page 39: ...of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off road engi...

Page 40: ...case breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FIRMAN POWER EQUIPMENT I...

Page 41: ...All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT PEORIA AZ 85381 1 844 347 6261 WWW FIRMANPOWEREQUIPMENT COM 8716...

Reviews: