Low Oil Shutdown
If the engine oil drops below a preset level, an oil switch will stop the engine. Check oil level with
dipstick.
If oil level is between the
LOW
and
HIGH
mark on dipstick:
1.Add oil to bring level to
HIGH
mark.
2.Restart engine and if the engine stops again a low oil condition may still exist. DO NOT try to restart
the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is corrected.
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the
LOW
mark on dipstick:
Overloading a generator in excess of its rated wattage capacity can result in damage to the
generator and to connected electrical devices. To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Do Not Overload Generator
Overload Operation
The overload indicator light will turn on when the load exceeds 1764W(approximately). If the load
exceeds 1860W(approximately), the light will blink and cut power to the receptacles in 30 seconds.
1. Disconnect any electrical devices, and then stop the engine.
3. Inspect the Air Inlet and Control Panel for any blockage. Remove blockage if found.
4. Restart Engine.
How to Correct
2. Reduce the total wattage of connected electrical devices until it is within the generator’s rated output.
Parallel Operation
Any two FIRMAN inverter generators with parallel ports, including two FIRMAN inverters model
W01785 can be paralleled to increase the total available electrical power to 3100 Watts. A FIRMAN
Parallel kit (not included) is required for parallel operation. For Kit availability, call customer Service at
1-844-347-6261 or visit: www.firmanpowerequipment.com.
English Customer Service: 1-844-FIRMAN1
Summary of Contents for W01785
Page 8: ...06 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...
Page 9: ...07 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...
Page 10: ...08 FEATURES AND CONTROLS English Customer Service 1 844 FIRMAN1...
Page 32: ...PARTS DIAGRAM AND PART LIST W01785 PARTS DIAGRAM 30 English Customer Service 1 844 FIRMAN1...
Page 33: ...80cc ENGINE PARTS DIAGRAM 31 English Customer Service 1 844 FIRMAN1...