background image

Page 30

 SPE175E 171cc Engine Parts List

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

330723500
330723501
330723502
330723503
330723504
330723505
330723506
330723507
330723508
330723509
330723510
330723511
330723512
330723513
330723514
330723515
330723516
330723517
330723518
330723519
330723520
330723521
330723522
330723523
330723524
330723525
330723526
330723527
330723528
330723529
330723530
330723531
330723532
330723533
330723534
330723603
330723604
330723537
330723538
330723539
330723540
330723541
330723542
330723543
330723544
330723545
330723546
330723547
330723548
330723549
330723550
330723551

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

NO. Part Number

Description

Qty.

Flange Bolt M8×35
Oil Seal
Cover,crankcase
Oil  Level  Sensor
Flange BOLT M6×12
Plate, Coil
Bearing 6205
Gasket,Crankcase Cover
Crankshaft
Woodruff key(4×6.5×16)
Lifter,Valve
Locating Pins

Cooling Fan
Pulley,Starter
Nut M14
Fan cover
Screw,Pawl Guide
Pawl Guide
Spring,Ratchet Guide
Patchet,Starter
Spring,Ratchet 
Reciol Starter Reel
Reciol Starter  Spring
Reciol Starter  Cover
Grip ,Starter
Rope Button
Rope (

φ

Wire Clip
Flange Bolt M6×8
Oil Nipple
Oil  Dipstick  Assembly
Camshafe Comp

Air Guide Board
Washer,Drain Bolt
Bolt, Drain
Ignition Coil
Flange  Bolt M6×20
Connecting Rod
Circlip
Piston Pin
Piston 
Ring Coil
Ring ,Second Piston
Ring ,First Piston
Gasket, Cylinder Head
Valve,Exhaust
Locating Pins
Cylinder Head
Oil Seal,Valve
Flange  Bolt M8×65

      

5×1550

6
2
1
1

11

1
2
1
1
1
2
2
2
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
2
1
1
2

330723552
330723553
330723554
330723555
330723556
330723557
330723558
330723559
330723560
330723561
330723562
330723563
330723564
330723565
330723566
330723567
330723568
330723569
330723570
330723571
330723572
330723573
330723574
330723575
330723576
330723577
330723578
330723579
330723580
330723581
330723582
330723583
330723584
330723585
330723586
330723587
330723588
330723589
330723590
330723591
330723594
330723595
330723596
330723597
330713514
330423500
330423501
330423502
330423503

53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

100
101

NO. Part Number

Description

Qty.

Guide Plate,Push Rod
Push Rod
Valve,Intake
Stud Bolt(M6×32)
Stud Bolt(M6×97)
Spark Plug(F6RTC)
Flange  Bolt M8×45
Spring,Valve
Retainer,Valve Spring
Valve Collet
Bolt,Rocker Arm
Rocker Arm ,Valve
Adjusting Nut,Valve
Lock Nut
Air Shroud,Cylinder

Breather Tube
Gasket,Insulator
Insulator,Carburetor
Carburetor,Assembly
Gasket, Air Cleaner
Base,Air Cleaner
Nut M6
Clapboard
Sealing Ring
Element,Air Cleaner
Cover,Air Cleaner

Spring,Connecter

Screw M5×10

Support,Stepper Motor

Stepper Motor Base

Screw M3×6
Cover,Stepper Motor 
Crankcase
Flywheel
Starter Motor
Relay,Starter
Gasket,Exhaust
Recoil Starter Set
Air Cleaner Set
Piston Rings Set
Gasket Set

1
2
1
2
2
1
2
2
2
2
2
2
2
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
2
1
1
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1

Seal Strip,Crankcase COVER

SCREW/Washer Assembly M5×10

Gasket,Cylinder Head Cover
Cylinder Head Cover Assembly

Connecter,Throttle Valve Axis

SCREW/Washer Assembly M5×10

SCREW/Washer Assembly M4×8

Stepper Motor ,Throttle Valve

Clamp Board,Choke Control Line
SCREW/Washer Assembly M5×8

Summary of Contents for W03082

Page 1: ... level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE INVERTER GENERATOR MODEL NUMBER W03082 Rev Level 01 DO NOT RETURN TO STORE CALL US FIRST CUSTOMER HOTLINE 1 844 347 6261 FOR QUESTIONS OR SERVICE INFORMATION Purchase Date ...

Page 2: ...ot Overload Generator 19 Parallel Operation 19 Introduction Battery Cable Connection Operation at High Altitude Starting the Generator Electric Start Connecting to a Building s Electrical English Customer Service 1 844 FIRMAN1 Maintenance And Storage 20 Maintenance Schedule 20 Engine Maintenance 21 Change Engine Oil 21 Air Filter Maintenance 21 Spark Plug Maintenance 22 22 Generator Maintenance 23...

Page 3: ...rmation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also m...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1 ...

Page 5: ...ide and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mudroom English Customer Service 1 844 FIRMAN1 ...

Page 6: ...hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive which could c...

Page 7: ...l loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Page 8: ... appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NOTE Improper treatment of generator could damage it and shorten its life UNPACKING THE GENERATOR Open carton and Remove packag...

Page 9: ...re the enclosed product may differ slightly from the image on this page 1 1 Fixed 2 Fuel Cap 3 Recoil Starter 4 Never Flat Wheel 5 Control Panel 6 Muffler Spark Arrester 7 Maintenance Cover Oil filler and air filter access 8 Folding Handle Carrying Handle English Customer Service 1 844 FIRMAN1 ...

Page 10: ...city has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Power Indicator Light Item 7 will go off The engine will continue to run but the red Engine Overload Indicator Light will stay on and power will no longer be supplied to connected electronic devices 1 3 2 3 1 Data Minder Multi Meter Push the SELECT button to show the Voltage Hertz and running h...

Page 11: ... protector may be reset by pushing the button of the protector Ground Terminal Consult an electrician for local grounding regulations 17 18 Outlet Cover Protect the receptacles from dust and debris Fuel Valve Knob Recoil Stater Choke Button 12V DC Battery Charger Port Plug the 120 Volt AC charger into this port to charge the generator battery 13 19 Battery Cable Connection 1 Unscrew the maintenanc...

Page 12: ... temperature altitude engine condition and etc Maximum power decreases about 3 5 for each 1 000 feet above sea level and will also decrease about 1 for each 10 F 6 C above 60 F 16 C ambient temperature Model Rated AC Voltage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacit...

Page 13: ...cause engine speed to vary and help seat piston rings CAUTION The unit is equipped with a low oil shutdown If the oil level becomes lower than required the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If eng...

Page 14: ...fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any spilled gasoline English Customer Service 1 844 FIRMAN1 Operation at High Altitude At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable The d...

Page 15: ...8000Feet OPEN WARNING The part number and recommended minimum altitude for the application of the high altitude carburetor main jet is listed in the table below Grounding The National Electric Code requires your generator must be properly connected to an appropriate ground to help prevent electric shock Failure to properly ground the generator can result in electric shock WARNING A ground terminal...

Page 16: ...sements crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even after this product has shut off ALWAYS place this product downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut ...

Page 17: ...y 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment 2 Check oil level and fuel 3 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 7 Pull the starter cord slowly until resistance is felt and then pull rapidly 9 Allow generator to run at no loa...

Page 18: ...the Generator Electric Start 2 Check oil level and fuel WARNING WARNING 1 Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment Electric Start Operations This model is provided with recoil start and electric start capabilities The charger is a low amperage maintenance type charger It will charge your battery as your generator runs...

Page 19: ...rectly into the generator Do not plug the generator into any electric outlet in your home Doing so could create a connection to the utility company power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be connected to a building electrical system consult your local utility company or a qualified...

Page 20: ...move entire electrical loads Never start or stop the generator with electrical devices plugged in or turned on Let the generator run at no load for two minutes to stabilize internal temperatures of the engine and generator CAUTION Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging WARNING ...

Page 21: ...ceptacles after 30 seconds when the load exceeds 3080W approximately Parallel Operation 1 DO NOT try to restart the engine 2 Contact an Authorized FIRMAN Service Dealer 3 DO NOT operate engine until oil level is corrected If oil level is below the LOW mark on dipstick 1 Disconnect any electronic devices and then stop the engine 2 Reduce the total wattage of connected electronic devices until it is...

Page 22: ...hould clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer ITEM NOTES Daily Before operation Initial 25 hours Every 50 hours Every 100 hours or annual Fittings Fasteners Spark Plug Engine Oil Air Filter Fuel Line Exhaust System Engine Check condition Adjust gap and clean Replac...

Page 23: ...ant Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Always keep the element clean d Put the element in the case and install it securely a Remove the air cleaner cover and locate the air filter plastic cover e Reattach the air filter cover f Reinstall the air cleaner cover and tighten the cover screw securely c After wetting the ele...

Page 24: ... follows Depending on the type fuel used the type and amount of lubricant used and or your operating conditions the exhaust part and muffler may become blocked with carbon deposits If you notice power loss you may need to remove these deposits to restore performance 1 Allow the engine to cool completely before servicing the spark arrester 2 Loosen the spark arrester clamp remove the spark arrester...

Page 25: ... attach spark arrester cover with the screws 3 Carefully remove the carbon deposits from the spark arrester screen with a wire brush Battery Replacement 1 Unscrew the air cleaner cover by provided screwdriver 2 Release the battery retaining rubber belt 3 Remove the protective cover rubber sheath from battery 4 Disconnect the black cable from black terminal on the battery Disconnect the red cable f...

Page 26: ...battery Charging The Generator Battery WARNING WARNING SERVICE AND STORAGE Infrequent Service If the unit is used infrequently difficult starting may result To eliminate hard starting follow these instructions 1 Run the generator at least 30 minutes every month 2 Run the generator then close the fuel shut off valve and allow the unit to run until the engine stops 3 Move the engine switch to the OF...

Page 27: ...sture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and storage 6 Change oil with recommended grade oil 8 Keep the engine switch and fuel valve on OFF position 9 Cover the unit and store in a clean dry place out of direct sunlight NEVER USE WATER TO CLEAN GENERATOR NOTE We recommend always using a fuel stabilizer A FUEL STABLIZER will ...

Page 28: ...pen or closed 13 Engine has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain fuel tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 1...

Page 29: ...Page 27 PARTS DIAGRAM AND PARTS LIST W03082 Parts Diagram English Customer Service 1 844 FIRMAN1 123 127 ...

Page 30: ...Page 28 171cc Engine Parts Diagram English Customer Service 1 844 FIRMAN1 ...

Page 31: ...porter Left Supporter Right 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Qty NO Part Number Description 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 2 2 2 2 2 1 1 8 2 1 1 1 1 8 1 1 1 1 1 2 2 1 3 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 330...

Page 32: ...1 1 1 1 1 2 2 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 1 2 1 1 2 330723552 330723553 330723554 330723555 330723556 330723557 330723558 330723559 330723560 330723561 330723562 330723563 330723564 330723565 330723566 330723567 330723568 330723569 330723570 330723571 330723572 330723573 330723574 330723575 330723576 330723577 330723578 330723579 330723580 330723581 330723582 330723583 330723...

Page 33: ...n material and workmanship for a period of one 1 year parts and labor and three 3 years parts from the original date of purchase 90 days parts and labor and 180 days parts for commercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the original purchaser and is not...

Page 34: ...ot apply to parts and or labor if your product is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty Other Exclusions This warranty excludes cosmetic defects such as paint decals etc wear items accessory parts f...

Page 35: ... failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on your small off road engine and engine powered equipment is defective the part will be repaired or replaced by FIRMAN small off road engine and engine powered equipment The California Air Resources Boa...

Page 36: ...old Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FIRMAN POWER EQUIPMENT INC Email support firmanpowerequipment com www firmanpowerequipment com 8 Throughout the emissions warranty period defined in Subsection b 2 FIRMAN will maintain a supply of warr...

Page 37: ...P N 330745451 Rev 05 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6 ...

Page 38: ...eso encendido eléctrico y encendido por control remoto El cargador es un cargador del tipo de mantenimiento a bajo amperaje El cargador le cargará la batería a medida que el generador funcione Evite encendidos prolongados ya que podrían dañar el motor Las baterías almacenadas emiten gas hidrógeno EXPLOSIVO mientras están cargándose No permita que se fume que hayan llamas abiertas chispas o equipos...

Page 39: ...eléctrico no se retroalimenta de las líneas eléctricas NOTA Economy Control Switch El Interruptor de economía puede activarse para minimizar el consumo de combustible y la emisión de ruido mientras se opera la unidad en momentos de generación eléctrica reducida permitiendo al motor permanecer en reposo durante los períodos en que no se usa La velocidad del motor se normaliza tras conectársele una ...

Page 40: ...l cable del cargador de batería negro a la terminal de batería negra 5 Encienda el generador NOTA Cuando el circuito de la batería está en uso la capacidad de CA se reduce por 100 watts Asegúrese de que la carga combinada está dentro de los límites evaluados PROTECTOR DEL CIRCUITO de corriente continua DC Un protector del circuito de CC se ha proporcionado para proteger al circuito de sobrecargas ...

Page 41: ...da el siguiente dispositivo 6 Permita que el motor se estabilice 7 Repita los pasos 5 6 para cada dispositivo adicional Operación de Sobrecarga La luz de indicador de sobrecarga se enciende cuando la carga excede 3080W aproximadamente Si la carga excede 3150W aproximadamente la luz parpadea y cortará la energía a los receptáculos en 30 segundos Cómo Corregir 1 Desconecte todos los dispositivos ele...

Page 42: ... haya fugas Volver a ajustar o reemplazar la junta si es necesario Revisar Reemplazar si es necesario Comprobar que no haya grietas u otros daños en la manguera de carburante Reemplazar si es necesario Recomendaciones Generales Reemplazar Revisar la rejilla del apagachispas Limpiar Reemplazar si es necesario ITEM Motor Comprobar ajustar Valve clearance Limpia la Cámara de combustión To be performe...

Page 43: ...er en ciertos animales de laboratorio Lave bien las zonas expuestas con agua y jabón Cambie el aceite del motor cada 100 horas para motores nuevos cambie el aceite cada 25 horas PRECAUCIÓN Mantenimiento del Filtro de Aire Utilice lubricante nuevo y de alta calidad en la cantidad especificada Si se utiliza aceite contaminado o deteriorado o si la cantidad del aceite del motor no es suficiente el mo...

Page 44: ...ba Los repuestos deben ser iguales e instalarse en la misma posición que las piezas originales e 0 8mm 0 028 a 0 031 Ajuste la distancia entre electrodos a 0 7 a f bujía de encendido en la posición de asiento y el hilo con la mano para evitar dañar las roscas g Apretar el tapón con una llave proporcionada y poner la tapa en la bujía c Retire la bujía usando la llave proporcionada b Retire de la bu...

Page 45: ... motor se degradará PRECAUCIÓN 3 Use un cepillo de alambre y elimine cuidadosamente los depósitos de carbono de la pantalla del parachispas Cambio de Batería 1 Desenrosque la tapa del filtro de aire con el destornillador suministrado 2 Suelte la correa de caucho de retención de la batería 3 Retire la cubierta protectora funda de goma de la batería 4 Desconecte el cable negro del cable negro termin...

Page 46: ...r en el puerto de carga del panel de control del generador Conecte el cargador a un tomacorriente de 120 voltios Spanish Servicio al Cliente 1 844 FIRMAN1 evitar daños a la batería y al generador SERVICIO Y ALMACENAMIENTO Servicio Infrecuente Si la unidad es utilizada pocas veces podría ser difícil de encender Para eliminar un encendido difícil siga las siguientes instrucciones 1 Haga funcionar el...

Page 47: ...de apagarse NO GUARDE EL GENERADOR SIN ESTABI LIZADOR DE COMBUSTIBLE EN EL SISTEMA DE COMBUSTIBLE INCLUYENDO TANQUE LÍNEAS DE COMBUSTIBLE Y CARBURADOR Cualquier daño o daño causado por el uso de combustible inadecuado combustible almacenado incorrectamente y o estabilizadores de formato incorrecto no están cubiertos por la garantía del fabricante No guarde gasolina de una estación a otra 4 FUEL ST...

Page 48: ...masiado abundante 12 La válvula de entrada está atascada abierta o cerrada 13 El motor ha perdido compresión 14 Filtro obstruido o sucio combustible está en posición OFF O 1 Ponga el interruptor del motor en posición ON I 2 Ponga la palanca de interrupción de combustible en posición ON I 3 Llene el cárter hasta el nivel adecuado o ponga el generador en una superfície nivelada 4 Limpie o reemplace ...

Page 49: ...DIAGRAMA DE LAS PIEZAS Y LISTA DE PIEZAS 27 Spanish Servicio al Cliente 1 844 FIRMAN1 W03082 Diagrama De Las Piezas 123 127 ...

Page 50: ...28 Spanish Servicio al Cliente 1 844 FIRMAN1 SPE175E 171cc Motor Diagrama De Las Piezas ...

Page 51: ...8 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Ensambledelprotectordelsilenciador másbajo Ensemble protecteur de silencieux supérieur Ensamblaje de tornillo arandela M4 14 Conjunto de tornillo arandela M3 10 NO Qty NúmerodePieza Descripción Manchon en caoutchouc couvercle d extrémité Supporter Couve...

Page 52: ...ire Base filtro de aire Tuerca M6 Tablilla Anillo de sellado Elemento filtro de aire Cubierta filtro de aire Spring Connecter Tornillo M5 10 Soporte Motor paso a paso Junta de sujeción Base del motor paso a paso Tornillo M3 6 Cubierta motor paso a paso Caja del cigüeñal Volante Motor de arranque Relé arrancador Junta escape Juego de filtro de aire Juego de anillos de pistón Juego de juntas 1 2 1 2...

Page 53: ...iódicamente repuestos y servicio para un buen desempeño Esta garantía no cubre la reparación cuando el uso normal haya agotado la vida útil de una parte o del equipo en su conjunto Esta garantía sólo se aplica al comprador original y no es transferible Si con este método no se soluciona el problema FIRMAN podrá a su elección autorizar la evaluación reparación o repuesto de la pieza o componente de...

Page 54: ...derechos legales que pueden variar de estado a estado Su estado puede que también tenga otros derechos a los que pueda acogerse y que no se mencionan en esta garantía Otras Exclusiones El mantenimiento normal no está cubierto por esta garantía Esta garantía excluye Defectos cosméticos como la pintura etiquetas etc Desgaste de objetos Piezas accesorias Fallos debido a hechos fortuitos y a otros aco...

Page 55: ...antiza al comprador final y a cada subsecuente comprador que el motor está Diseñado fabricado y equipado para cumplir con todas las regulaciones aplicables asoptadas por la Junta de Recursos de Aire y EPA Agencia de Protección Ambiental de Estados Unidos y libre de defectos en materiales y mano de obra que causen el fallo de una pieza garantizada que debe ser indéntica con referencia a todos los m...

Page 56: ...aje del silenciador catalítico incluyendo Colector del escape Convertidor catalítico Junta del silenciador Válvula de tensión 4 Sistema de inducción por aire incluyendo Tubería de entrada colector Filtro de aire 5 Ensamblaje del respiradero del cárter incluyendo Tubo de conexión del respiradero 6 Sistema de control de las emisiones de evaporación del depósito de combustible incluyendo Válvulas de ...

Page 57: ...os Cualquier reimpresión o uso no autorizado sin la autorización por escrito queda explícitamente prohibido P N 330745451 Rev 05 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6 ...

Reviews: