English Customer Service: 1-844-FIRMAN1
32
Maintenance - Storage
Battery Replacement
1.Unscrew the air cleaner cover by provided screwdriver.
2. Release the battery retaining rubber belt.
3
.
Remove
the protective cover(rubber sheath) from battery.
4. Disconnect the black(-) cable from black(-) terminal on the battery.
Disconnect the red(+) cable from red(+) terminal on the battery.
Rubber Sheath
Battery
Po)
Terminal
Negative(-)
Terminal
6. Install the new battery with following specification:
5. Remove the battery and recycle and dispose of properly.
12V sealed lead acid 5.5AH
LXWXH:
(
)
3.54X2.76X3.84 in. 90X70X100mm
7
.
Connect the red(+)battery cable to the positive terminal of battery first and then connect the black(-)
battery cable to the negative terminal of battery.
8. Reattach the air cleaner cover.
Red Cable
Black Cable