FEATURES AND CONTROLS

 

1- Fixed 
2- Fuel Cap
3- LPG

 

Hose Quick Connect Inlet

4- Recoil Starter
5- Never Flat Wheel
6- Control Panel
7- Muffler/Spark Arrester
8- Folding Handle 

Carrying Handle

9- Maintenance Cover – 

Oil filler and 

     air filter access.

10- LPG Hose with Regulator
11- Spring Clamp to Hang Regulator 
       on Handle

12- Data Decal / Serial Number

Summary of Contents for WH03242

Page 1: ...P N 332745482 Rev 01 OPERATOR S MANUAL DUAL FUEL INVERTER GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER WH03242 Rev Level 01...

Page 2: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Page 3: ...rt This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplyin...

Page 4: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 5: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Page 6: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Page 7: ...on this page 05 FEATURES AND CONTROLS 1 Fixed 2 Fuel Cap 3 LPG Hose Quick Connect Inlet 4 Recoil Starter 5 Never Flat Wheel 6 Control Panel 7 Muffler Spark Arrester 8 Folding Handle Carrying Handle 9...

Page 8: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 10: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 11: ...20 Amps current may be drawn from this duplex receptacle 5 120V 30A RV NEMA TT 30R A maximum of 26 7 Amps current may be drawn from this receptacle 6 Output Ready Indicator Light Remains ON during no...

Page 12: ...xternal short circuit occurs the circuit protector will trip 14 Parallel Operation Outlets These outlets are used for connecting two FIRMAN inverter generators for parallel operation A FIRMAN parallel...

Page 13: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 14: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 15: ...l for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage due to operation w...

Page 16: ...oil level may not be high enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is correc...

Page 17: ...ative main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude can...

Page 18: ...CSA B149 1 Natural Gas and Propane Installation Code as applicable If possible the fuel supply connection should be close to the outdoor operating location This will reduce the cost of the flexible fu...

Page 19: ...portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 4 Disconnect all electrical loads from the generator Never start or stop the generator with electrical...

Page 20: ...e plugging in any electrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 10...

Page 21: ...are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet 6 m from any occupied spaces 3 Connect the LPG hose with regulator to both LPG cylinder and portable gen...

Page 22: ...step 13 10 For recoil start only PULL TO PRIME Pull the starter cord 1 2 times Pull slowly until resistance if felt and then pull rapidly 7 Flip the engine switch to the RUN l position 8 Push the batt...

Page 23: ...re situations it can be helpful to Exchanging fuel cylinders to allow the first cylinder to warm up repeating as necessary Placing the LPG cylinder at the end of the generator near the handle where en...

Page 24: ...position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the first item It is best to attach the item with the l...

Page 25: ...e FIRMAN authorized service dealer Yellow light will blink for five seconds at the startup of generator to show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior t...

Page 26: ...lly NOTICE Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in the area while charging WARNING Battery electrolyte...

Page 27: ...et the generator run at no load for one minute to stabilize internal temperatures of the engine and generator 25 OPERATION 3 Turn the main fuel selector switch in this position to LPG position 1 30 o...

Page 28: ...ral minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 Plug in and turn on the next item 6 Allow the...

Page 29: ...lter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable experienced owner or by authorized...

Page 30: ...ith used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSER...

Page 31: ...s oil Spark Plug Maintenance Changing the spark plug will help your engine start easier and run at peak performance a Remove the maintenance cover b Remove the spark plug boot c Remove spark plug usin...

Page 32: ...with a spark arrester as defined in Section 4442 maintained in effective working order Other states or federal jurisdictions may have similar laws reference Federal Regulation 36 CFR Part 261 52 30 M...

Page 33: ...e spark arrester in the muffler and attach spark arrester cover with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make...

Page 34: ...ry Disconnect the red cable from red terminal on the battery Rubber Sheath Battery Positive Terminal Negative Terminal 6 Install the new battery with following specification 5 Remove the battery and r...

Page 35: ...aintain a proper charge if the portable generator is used on a regular basis about once every two weeks If it is used less frequently we can use the supplied charger plugged into the generator 12V DC...

Page 36: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 37: ...line 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Drain gas tank and carburetor fill with fresh gasoline 9 Wait 5 minutes and re crank...

Page 38: ...thane Type Yes FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Recoil Electric English Customer Service 1 844 FIRMAN1 AC Grounding System Neutral Floating 36 Troubleshooting Specificati...

Page 39: ...PARTS DIAGRAM AND PART LIST WH03242 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 37...

Page 40: ...193cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 38...

Page 41: ...Rear Cover Cage Nut M5 Bolt M6 16 Screw M5 14 Protector Rear Cover Screw M6 12 Right Cover Screw M5 14 Handle Right Spring Leaf Rubber Seal Sleeve Screw St4 2 9 5 Cover Right Muffler Cover Right Side...

Page 42: ...eed Limiter Nut M3 Micro Switch Control Panel Lpg Inlet Cover Screw M4 14 Fuel Valve Knob Screw M4 14 Lgnition Switch Switch economy Receptacle Cover DC 12V Indicator Light Receptacle Cover TT 30R Eng...

Page 43: ...1 1 2 2 1 1 1 4 1 1 1 1 2 1 1 2 1 1 1 2 1 2 1 1 1 2 2 1 1 4 1 1 1 1 1 2 1 2 1 1 1 6 1 1 2 1 1 1 1 1 2 2 2 1 1 1 1 2 2 2 2 2 2 2 2 1 2 2 1 1 1 1 1 4 2 1 2 1 1 1 1 1 2 2 1 1 1 1 2 1 2 1 1 1 1 2 1 2 1 1...

Page 44: ...English Customer Service 1 844 FIRMAN1 42 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 45: ...ercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the original...

Page 46: ...ct Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8716 W Ludlow Dr Suite 6 www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are h...

Page 47: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Page 48: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 49: ...l rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8716 W LUDLOW DR SUITE 6 PEORIA AZ 85381 1 844 347 6261 WWW FI...