background image

User’s Manual

Kitchen Fire Extinguishers

IMPORTANT! Please read carefully and save.

This user’s manual contains important information about your fire extin-
guisher’s operation. If you are installing this fire extinguisher for use by
others, you must leave this manual—or a copy of it—with the end user.

Read extinguisher label and the entire user’s manual carefully before
installing or using the unit. Make sure everyone in your household is
completely familiar with the operation of the extinguisher, and review
the instructions regularly. In an emergency, you will not have time to
read instructions.

IMPORTANT INFORMATION ABOUT 
FIRE EXTINGUISHERS

NOTE: Be sure the extinguisher is rated to fight the type of fire 
most likely to occur in the area you choose to install it. Since house-
hold fires commonly start in the kitchen, you should always install 
an extinguisher in the kitchen. For added security, you should also
install additional extinguishers in utility areas, and other living areas in
your household.

Model KFE2S5 is rated 5-B:C. 
This unit is NOT rated to fight Class A fires.

READ BEFORE INSTALLING OR USING 
THIS FIRE EXTINGUISHER!

Fire extinguishers are classified by fire type. The A, B and C 
rating system defines the kinds of burning materials each fire
extinguisher is designed to fight. The numbers in front of the 
A, B, or C indicate the rating for size of the fire the unit can
extinguish. Using the wrong type of fire extinguisher can do
more harm than good. Make sure you understand which fire
extinguisher to use on each class of fire!

Class A rating: The agent/powder is suitable for 
fighting small fires involving wood, paper, cloth, 
rubber, and some plastics.
Class B rating: The agent/powder is suitable for 
fighting small fires involving grease, oil, gasoline,
kerosene, and other flammable liquids.
Class C rating: The agent/powder is suitable for 
fighting small fires in "live" electrical equipment.

WHERE TO INSTALL THIS EXTINGUISHER

A Fire Extinguisher Should Be Mounted:
• 

In the vicinity of (but not on or in) a potential source of heat
and/or fire, like an oven or stove.

• 

Where it is easy to reach, near an exit or an escape route from
the room.

• 

In a location that is convenient, in plain sight, and 3-1/2 to 5
feet (1 to 1.5 meters) above the floor.

• 

Store the extinguisher high enough to keep it out of the reach
of small children.

• 

On a clean, dry surface where the temperature does not go
above 120° F (49° C) or below –40° F (–40° C).

HOW TO INSTALL THIS EXTINGUISHER

NOTE: 

Since wall surface types vary, mounting screws are not

included.

Purchase screws or bolts specifically designed for the sur-

face on which you will mount the fire extinguisher. The fire extinguisher
label lists its maximum weight.

If you do not mount the fire extinguisher on the wall, you must
remove the cap and store it separately. Failure to remove the cap
from a free-standing extinguisher may prevent it from working
properly in an emergency.
1.

Hold the extinguisher with the
back (mounting surface) of the 
cap facing you. Make sure to
hold the metal canister, not the 
plastic cap.

2.

Grasp the rectangular release
handle on the back of the cap.
Pull the handle up to remove
the cap/bracket from the 
extinguisher as shown.

3.

Install the mounting bracket on a
wooden stud or other solid surface that
will support the weight of the extin-
guisher. Use 1-1/4” (3.17 cm) long #8
pan or round screws with a #8 washer
as shown. Choose at least two of the
six holes provided on the Mounting
Bracket/Cap. Using two holes that are
opposite each other (i.e. the top and
bottom center holes) is recommended.
Mounting screws are not included (see
Note above.)

4. After installing the mounting bracket,

replace the extinguisher on the bracket with
the label facing outward, so the label can
be easily read.

Do not mount the extinguisher on drywall or plaster without
adequate support. Use strong screws or bolts to mount the
bracket securely into solid wood or metal that can support it,
like a wooden partition stud. Secure mounting is needed so
you can remove the extinguisher quickly and easily in an emer-
gency. Also, if the extinguisher is not held securely, it could
drop to the floor and injure people or damage the extinguisher.

Do not break the plastic loop holding the safety pin in place!
This loop prevents accidental discharge of the fire 
extinguisher. Break the loop only in an emergency before
using the fire extinguisher.

HOW TO OPERATE YOUR FIRE 
EXTINGUISHER IN A FIRE EMERGENCY

TO FIGHT THE FIRE

1.

Remove the extinguisher from the mounting bracket.

2.

Hold the unit firmly with the nozzle facing away from you. Pull out
the pin to break the “Safety Seal”. You won’t be able to squeeze
the trigger until the safety seal is removed. 

3.

Stand back 6 feet (2 meters) from the fire and make sure the fire
is not between you and your exit.

4.

Hold the extinguisher upright and aim the nozzle at the base 
of the fire.

5.

Press and hold the trigger to discharge the powder.

6.

Sweep the spray at the base of the burning material, using quick
side-to-side motions. (If the spray scatters the fire, move back.)

7.

Move slowly towards the fire as the extinguisher spray pushes the
fire back. Maintain a 6-foot (2 meter) distance between you and
the front of the fire at all times.

8.

Completely discharge the contents of the extinguisher and make
sure the fire is completely out. Flashbacks are common with fires.

9.

For kitchen fires on a kitchen stove, turn off the stove immediately
if possible, otherwise as soon as it is safe.

10. If you suspect a fire had an electrical origin, shut off the electrical

power, if possible, without eliminating your escape route. Do not
touch electrical wires or appliances.

11. After you have completely discharged your extinguisher, leave the

building and close all the doors behind you.

AFTER THE FIRE IS EXTINGUISHED

Do not turn the electrical power back on or plug in any appliances
until the area has been cleaned up completely. It is very important
to remove the powder from electrical equipment after a fire. If the
powder gets wet, it can conduct electricity. (Using a dry chemical
extinguisher on wet electrical equipment may be hazardous for this
reason.) This may worsen an electrical leakage problem, impair the
equipment’s insulation, or create an electrical shock hazard.

If the fire was on a kitchen stove:

Make sure the oven and all burners are turned off.

Clean up the powder completely before using the stove or oven.
See “How to Clean After Using a Fire Extinguisher”. Ventilate the
area thoroughly.

If you think the fire had an electrical origin:

Shut off the electrical power, if possible--do not touch any 
electrical wires or appliances.

Leave the building and close all doors behind you. Call the Fire
Department and have them inspect the entire house. As soon as
they say it’s safe to return, ventilate the area thoroughly.

Have a licensed electrician inspect your electrical system. Do not
turn the power back on or plug in any electrical equipment until
the inspection has been completed.

Make sure your extinguisher may be safely and effectively
used on the small fire you want to fight. Always use extreme
caution when fighting any fire. Fight a fire only where there is
a clear escape path to allow you to get out safely if the fire
gets worse.

Avoid breathing smoke and heated fumes; stay low if 
necessary. Burning materials will release toxic fumes.
Inhaling these fumes may cause injury or death.

Always stand back far enough away from the fire—near an
exit—and make sure nothing is between you and your
escape route. If you get too close to a fire, you risk getting
burned or hit by splattering material like grease. If the fire 
is too hot or smoky for you to get within 6 feet (2 meters),
DO NOT try to fight the fire yourself. Evacuate immediately
and call the Fire Department.

For fires on a kitchen stove, turn oven or burners off 
immediately if possible. If you can’t reach the oven or burner
controls safely, extinguish the fire first, then turn them off.

Fight the fire from an upwind direction with your back to any
strong air current. Trying to fight a fire with currents blowing
towards you can result in serious injury.

IF YOUR EXTINGUISHER NEEDS SERVICE

This fire extinguisher is a disposable device that is NOT rechargeable.

Do not try to service or repair this fire extinguisher under any 
circumstances. Do not try to remove the nozzle or valve assembly.
This is a pressurized device that can cause serious injury if 
tampered with.

If there is a problem and it is still under warranty, please see “How to
Obtain Warranty Service” in the Limited Warranty.

DISPOSING OF A USED EXTINGUISHER

Completely discharge the extinguisher outdoors by turning the unit
upside down and pulling the trigger. Dispose of the empty unit 
properly and replace it with a new fire extinguisher.

Never puncture, burn or expose this fire extinguisher to tempera-
tures over 150° F (66° C) even if it is fully discharged. The contents
are under pressure and it could explode.

LIMITED WARRANTY

BRK Brands, Inc. ("BRK") the maker of First Alert

®

brand products,

warrants that for a period of ten years from the date of purchase, this
product will be free from defects in material and workmanship. 
BRK, at its option, will repair or replace this product or any component
of the product found to be defective during the warranty period.
Replacement will be made with a new or remanufactured product or
component. If the product is no longer available, replacement may be
made with a similar product of equal or greater value. This is your
exclusive warranty.

This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.

This warranty does not cover normal wear of parts or damage result-
ing from any of the following: negligent use or misuse of the product,
use on improper voltage or current, use contrary to the operating
instructions, disassembly, repair or alteration by anyone other than
BRK or an authorized service center. Further, the warranty does not
cover acts of God, such as fire, flood, hurricanes and tornadoes.

BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except 
to the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty. Some states, provinces, or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have
other rights that vary from state to state, or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your 
retailer. In order to obtain warranty service, contact the Consumer
Affairs Division at 1-800-323-9005, 7:30 AM to 5:00 PM, Central
Standard Time, Monday through Friday. To assist in serving you, please
have the model number and date of purchase available when calling.

Address: 25 Spur Drive, El Paso, TX 79906

Printed in Mexico   M08-0037-009   M

02/13

1

2

3

4

TABLE OF CONTENTS

Important Information About Fire Extinguishers . . . . . . . . . . . . . . .1
Read Before Installing or Using This Fire Extinguisher  . . . . . . . . .1
Where to Install This Extinguisher  . . . . . . . . . . . . . . . . . . . . . . . . . .2
How to Install This Extinguisher  . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Checking and Inspecting the Fire Extinguisher  . . . . . . . . . . . . . . .2
How to Operate Your Fire Extinguisher in a Fire Emergency  . . . .3
After the Fire is Extinguished  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How to Clean After Using a Fire Extinguisher . . . . . . . . . . . . . . . . .4
If Your Fire Extinguisher Needs Service . . . . . . . . . . . . . . . . . . . . . .4
Disposing of a Used Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
© 2013 BRK Brands, Inc.  All rights reserved.  Distributed by 
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005   •   www.firstalert.com

Printed in Mexico
M08-0037-009   M

02/13

Remove Extinguisher

from Bracket/Cap

Break the

Safety Seal

Press and Hold

Trigger To

Discharge Powder

This extinguisher is designed for use against small fires 
that have just started and are small enough to fight safely. 
It is not designed to fight large fires that are burning out of
control. If the fire is too hot or smoky for you to get within 
6 feet (2 meters) of it, do not try to fight it yourself. Warn
everyone, evacuate the premises, and have someone call
the Fire Department from outside the building. Trying to 
fight a large fire yourself can result in injury or death.

Do not puncture or burn any fire extinguisher. The contents
are under pressure, and the extinguisher could explode.

Never locate this extinguisher close to an engine, stove or
other source of heat. It is pressurized and could rupture or
explode if exposed to temperatures over 150° F (66° C).

This extinguisher contains a dry powder extinguishing agent.
The agent/powder is nontoxic, but can irritate skin. When using
this unit, avoid breathing the powder. Always ventilate the area
after use.

First Alert

®

is a registered trademark of the First Alert Trust.

This unit will not operate with mounting bracket attached. 
The extinguisher must be removed from the mounting bracket 
or it cannot discharge its contents to fight a fire.

Kitchen

Fire

Extinguisher

Model KFE2S5

Mounting Surface

Release Handle

Metal

Canister

Plastic Mounting

Bracket/Cap

CHECKING AND INSPECTING 
THE FIRE EXTINGUISHER

1.

Inspect and test the extinguisher once a
week. Start by removing the extinguisher
from the mounting bracket/cap. Check the
extinguisher pressure by pressing the green
button on top of the cap as shown in
“Checking the Pressure.” If the button pops
back up, the extinguisher is properly pres-
surized and ready to use. If the button stays
down, the extinguisher has lost pressure
and must be replaced.

2.

Check for signs of damage or misuse. Make sure you can still
read all the text on the label. Carefully examine the surface of 
the extinguisher for corrosion. You can help prevent corrosion 
by cleaning the extinguisher if it gets wet or dirty. If you notice
corrosion during the warranty period, return the unit to First Alert

®

(See "Limited Warranty" at the end of this manual).

3.

Make sure the tamper indicator 
(“safety seal”) is still intact as shown in
“Location Of The ‘Safety Seal’” and the 
nozzle is clean and unobstructed.

4.

When you finish inspecting the fire 
extinguisher, always put it back into the
mounting bracket. Make sure the handle is
locked down and the safety seal is intact.

For more information about fire extinguishers, consult the NFPA
Standard #10, “Portable Fire Extinguishers,” available from the
National Fire Protection Association, Inc., Batterymarch Park, Quincy,
MA 02169, USA.

HOW TO CLEAN AFTER USING A FIRE
EXTINGUISHER

NOTE: The powder spray from the extinguisher may spread over a
wide area, and may soil upholstery, carpets and walls.

Sweep/vacuum up as much of the powder as possible. Then use
a damp cloth to wipe off the remaining agent.

If you have any questions about cleaning appliances that the
agent has come into contact with, please contact the appliance
manufacturer.

DO NOT CHECK THE PRESSURE OR TEST THE FIRE 
EXTINGUISHER BY SQUEEZING THE TRIGGER, EVEN BRIEFLY.
ONCE USED IT WILL GRADUALLY LOSE PRESSURE AND WILL
NOT BE FULLY CHARGED FOR USE IN AN EMERGENCY.

Checking the

Pressure

Location of the

“Safety Seal”

Tested to 

ANSI/UL 711 

and ANSI/UL 299

Reviews: