background image

IMPORTANT! 

PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by 
others, you must leave this manual—or a copy of it—with the end user.

USER’S MANUAL

M08-0049-002   K1 07/04   Printed in Mexico

Model SA710

TABLE OF CONTENTS

Fire Safety Tips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm  . . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Optional Locking Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Weekly Testing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regular Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If This Smoke Alarm Sounds  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
What To Do In Case Of Fire  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
If You Suspect A Problem  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Limited Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Recommended Locations For Smoke Alarms  . . . . . . . . . . . . . . .5-6
Locations To Avoid For Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . .6
About Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Special Compliance Considerations  . . . . . . . . . . . . . . . . . . . . . . . .7
Limitations Of Smoke Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
All Rights Reserved. © 2004 BRK Brands, Inc. 
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com

*All First Alert

®

Smoke Alarms conform to regulatory requirements,

including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.

Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible

materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.

Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for

hours before bursting into flame. Sources of these fires may include cig-
arettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.

This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impaired residents.

Do not connect this unit to any other alarm or auxiliary device.
It is a single-station unit that cannot be linked to other
devices. Connecting anything else to this unit may prevent it
from working properly.

Unit will not operate without battery power. The Smoke
Alarm cannot work until you install the battery in the correct
position (Match “+” to “+” and “-” to “-”).

This Smoke Alarm has a battery drawer which resists closing
unless a battery is installed.

Do not install this unit over an electrical junction box. Air cur-
rents around junction boxes can prevent smoke from reaching
the sensing chamber and prevent the unit from alarming. Only
AC powered units are intended for installation over junction
boxes.

Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn
at close range may harm your hearing. 

Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.

1

SMOKE AND FIRE* ALARM

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers; 
4) Keep electrical appliances in good condition and don’t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’t let rubbish accumulate.

Keep alarms clean, and test them weekly. Replace alarms immediately if
they are not working properly. Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every
floor, and an additional one in the kitchen. Have fire escape ladders or
other reliable means of escape from an upper floor in case stairs are
blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

Important! Read “Recommended Locations for Smoke Alarms” and
“Locations to Avoid for Smoke Alarms” before beginning. This unit mon-
itors the air, and when smoke reaches its sensing chamber, it alarms. It
can give you more time to escape before fire spreads. This unit can
ONLY give an early warning of developing fires if it is installed, main-
tained and located where smoke can reach it, and where all residents
can hear it, as described in this manual. This unit will not sense gas,
heat, or flame. It cannot prevent or extinguish fires.

Understand The Different Type of Smoke Alarms

Battery powered or electrical? Different Smoke Alarms provide 
different types of protection. See “About Smoke Alarms” for details. 

Know Where To Install Your Smoke Alarms

Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping area. See “Recommended Locations
For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for
details.

Know What Smoke Alarms Can and Can’t Do

A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See “Limitations of Smoke Alarms” for details. 

Check Your Local Building Codes

This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requirements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.

Summary of Contents for SMOKE AND FIRE ALARM

Page 1: ...e sensing chamber and prevent the unit from alarming Only AC powered units are intended for installation over junction boxes Do not stand too close to the unit when the alarm is sounding It is loud to wake you in an emergency Exposure to the horn at close range may harm your hearing Do not paint over the unit Paint may clog the openings to the sensing chamber and prevent the unit from operating pr...

Page 2: ... if necessary until they are flush with the ceiling or wall 6 Attach the mounting bracket to the ceiling or wall 7 Install the battery included Open the battery drawer Match the terminals on the end of the battery with the terminals on the unit Match to and to Push the battery in until it snaps in securely and cannot be shaken loose If the battery is not snapped in completely the unit cannot recei...

Page 3: ...or alarm removal is not a concern These Smoke Alarms have two separate locking features one to lock the battery compartment and the other to lock the Smoke Alarm to the mounting bracket You can choose to use either feature independently or use them both Tools you will need Needle nose pliers or utility knife Standard flathead screwdriver Both locking features use locking pins which are molded into...

Page 4: ... maintenance free as possible but there are a few simple things you must do to keep it working properly Use only the replacement batteries listed below The unit may not operate properly with other batteries Never use rechargeable batteries since they may not provide a constant charge Test it at least once a week Clean the Smoke Alarm at least once a month gently vacuum off any dust using your hous...

Page 5: ...amages or limitations on how long an implied warranty lasts so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province How to Obtain Warranty Service Service If service is required do not return the product to your retailer In order to obtain warranty service conta...

Page 6: ... 20 feet 6 meters from the sources of combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6 meter distance is not possible in modular mobile or smaller homes for example it is recommended the Smoke Alarm be placed as far from these fuel burning sources as possible The placement recommendations are intended to keep these Alarms at a reasonable distance ...

Page 7: ...e fires may not reach the unit immediately Examples of this include persons smoking in bed children playing with matches or fires caused by violent explosions resulting from escaping gas Smoke Alarms are not foolproof Like any electronic device Smoke Alarms are made of components that can wear out or fail at any time You must test the unit weekly to ensure your continued protection Smoke Alarms ca...

Reviews: