19
Maintenance & Troubleshooting
To ensure maximum lifespan and optimal performance follow these steps:
1.
Keep your E820A in a dry, clean climate controlled environment at room
temperature.
2. Only
treat water with FDF genuine Water
Treatment
Tablets. Refer to ‘water
treatment’ section on page 14.
3. Periodically
clean your machine with disinfectant, applied using a lint free cloth.
4.
Wipe
dust
off the machine.
5.
For
information
on how to service your machine visit
firstdegreefitness.com/support
Item
Time Frame
Instructions
Seat and Frame.
Weekly.
Wipe down weekly with lint free cloth or more often with
heavy club use.
PK Belt Tension.
Monthly.
Check monthly for signs of slippage. Adjust/tighten as
required.
Tank and Water
Treatment.
12 months to 2 years.
Follow instructions as specified in the “Water Treat-
ment” section of this manual.
Chain Drive.
Check every 100 hours for
correct
tension.
Open the inspection plate and check tension using a
screwdriver or other tool. Tighten as required using
chain tensioning Bolts located at the end of the control
arm.
Handle Assembly.
Check weekly using Multi-
Tool (supplied) to ensure
Handle Assembly is
securely tightened into
Crank Arm.
The handle should be checked on a regular basis.
Continued use of a loose Handgrip can cause
damage to the Crank Arm threads, necessitating
replacement.