9

Pump Motor Diagram:

Problem

: Water Motor does not click. Water does not flow past unit.

•  Cause: No water flow to motor.

•  Solution: Check that water is flowing to Flex-Chlorinator.

•  Cause: Incoming water is connected to the outlet side of the pump 

motor.

•  Solution: Verify that the incoming water is connected to the inlet 

(right side) of the pump motor.

Problem

: Water Motor does not click. Water does flow past unit.

•  Cause: Water motor is in “bypass” due to damaged parts on the in-

side of water motor or excessive wear of moving parts.

•  Solution: Contact First Water for support.

Problem

: Motor click a few times then stops.

•  Cause: Unit is in bypass condition.

•  Solution: Shut off water. Relieve pressure at the air vent. Restart wa-

ter.

•  Cause: Clogged chemical feed tube.

•  Solution: Inspect tube for blockage.

•  Cause: Motor may be in bypass due to damaged internal parts.

•  Solution: Contact First Water for support.

•  Cause: O-Ring on pump stem may have excessive wear.

•  Solution: Contact First Water for support.

Troubleshooting

Summary of Contents for Flex-Chlorinator

Page 1: ...1...

Page 2: ...2 Table of Contents Operation and Maintenance Safety 4 Chemical Preparation 5 Operation 7 Pump Maintenance 8 Troubleshooting 9 General Maintenance 11 Warranty 12...

Page 3: ...d or a First Water representative The information and component de scriptions in this guide are accurate at the time of writing The illustrations in this guide repre sent the typical assembly and op e...

Page 4: ...e risk follow proper installation methods and instructions The point of chemical injection should be beyond all pumps filters and heat ers NEVER use chlorine with fragrance perfume of detergent additi...

Page 5: ...0 ppm of free chlorine residual present this ensures the water does not have an unpleasant taste or odor 2 At 24 hours after the addition of sodium hypochlorite to containers that are used by families...

Page 6: ...not the final desired residual chlorine 1 Open the case and remove the Chlorine Dilution Containers 2 Follow the chart below to achieve the proper dilution of household bleach CAUTION never use bleach...

Page 7: ...until all trapped air is released 5 Warning The Chlorine Dilution Container must be continually moni tored to ensure your water treatment system does not continue to oper ate after the chlorine soluti...

Page 8: ...o fit into the key on the inside of the water motor 3 After installing pump into bottom of water motor loosen Jaco nut on pump and insert hose into fitting Re tighten Jaco nut 1 Make sure the water is...

Page 9: ...ast unit Cause Water motor is in bypass due to damaged parts on the in side of water motor or excessive wear of moving parts Solution Contact First Water for support Problem Motor click a few times th...

Page 10: ...heck for broken or worn pump stem at tip Pump stem must be pulled out completely before being inserted into the water motor Cause Damaged pump Solution Contact First Water for support Problem Chlorine...

Page 11: ...ide of opening on bottom cap of water motor with tooth brush white vinegar Chemical Pump 1 Clean pump after use by running 5 gallons of clean water through the pump or by removing the pump and hand cl...

Page 12: ...work done without first obtaining First Water Systems Inc s written consent This warranty is made expressly in lieu of all other warranties expressed or implied including any implied war ranties or m...

Reviews: