Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2018 Fi rst ech ,
LLC.
Page 18
Pin 16 Red/White - Door zone input (-): This wire monitors negative (-) trigger door-pins for security and turbo
timer purposes the proper wire in the vehicle, will provide a negative (-) trigger only when the doors are
opened. You will need to test the wire for correct polarity.
Pin 17 Brown - Siren: 600mA (+) output can be connected to the positive lead of an aftermarket siren. This
will produce output with arm/disarm, full alarm, and panic as a default setting. This can be changed
based on feature 3-09 option settings. The length of output for the arm/disarm chirps can be
changed using feature 3-02 settings.
Pin 18 Blue/white - Starter Kill: 250mA latched negative (-) output when armed and during remote start
(while running) that can be used with an FT E-LOCK to interrupt a starter wire protecting from
theft or grinding the starter during take over. Caution: If this wire is being used to trigger multiple
aftermarket accessories it must be diode isolated for each one.
Connector 3 (CN3) CM900S White 12 pin Input/Output harness (I/O harness)
Pin 1 Green/White - (fixed output) Parking light 250mA negative (-) output. This will provide output whenever
the parking lights are activated for lock, unlock, remote start, diagnostics, and programming the proper
wire in the vehicle will test (-) when the parking light switch is in the on position.
Note: There are 18 additional POC setting options for this POC.
Pin 2 Blue/Lt. Green - [POC 2] Lock 250mA, 800mS (-) negative output: This is an optional output that
will provide only negative (-) output pulse for locking doors. System will lock doors and arm alarm.
IMPORTANT: You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT- DM600
or relays. For additional lock settings review Option Group 1.
Note: There are 18 additional POC setting options for this POC
Pin 3 Blue - [POC 3] Unlock 250mA, 800mS (-) negative output: This is an optional output that will provide only a
negative (-) output pulse for unlocking doors. System will unlock doors and disarm alarm. IMPORTANT:
You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT- DM600 or relays. For
additional lock settings review Option Group 1.
Note: There are 18 additional POC setting options for this POC
Pin 4 Black - [POC 4] Status/Ground while running (GWR) 250mA latched negative (-) output: This is an optional
output that will provide a latched negative (-) output 250mS before the ignition turns on, stays on throughout
the remote start duration and will be the last to shut off. This wire is most commonly used to trigger bypass /
transponder modules. Note: There are 18 additional POC setting options for this POC
Pin 5 Orange - [POC 5] Factory Alarm Arm (FAA) 250mA, 800mS negative (-) output: This is an optional output
that will provide a (-) pulse during lock, after crank and again after the remote start shuts down. The FAA
output timing can be configured using feature 1-05.
Note: There are 18 additional POC setting options for this POC