2-13 Timer Mode: (Note: Must be set to on to operate timer mode). This feature enables the user to activate and
deactivate Timer Mode (see option 2-06) using the Firstech remote or accessory (see the user manual for
that remote for instructions).
FO1 - Off: (default)
FO2 - On: user must still activate timer mode using their Firstech remote or accessory.
2-14 Turbo Timer activation
“
Activate
with”
: CM900AS ONLY
This feature will allow the user to customize the process used to activate the turbo timer feature Once
user has activated turbo timer feature, there is a 5-minute
window to “Start Timer”
the CM cancels
Turbo Timer feature. NOTE: a door input must be connected to allow Turbo Timer to continue to
run after exiting the vehicle.
FO1
–
Parking/E-Brake set: When set to this option, when the CM sees the parking/E-Brake input
(analog or through data) it will activate the necessary ignition, accessory outputs and interface
module, to leave the vehicle running and activate Turbo Timer Mode.
FO2
–
Parking/E-Brake set + Hold Start button for 2.5 seconds: When set to this option, the
CM will need Parking/E-Brake input (analog or through data) AND a start command from a remote
(hold start button for 2.5 seconds) to activate the necessary ignition, accessory outputs and interface
module, to leave the vehicle running and activate Turbo Timer Mode.
FO3
– 2x’s Parking/E
-Brake: (requires action) Set => Release => Set (within 7 seconds): When
set to this option, the CM will need Parking/E-Brake input (analog or through data) set then release
then set again within 7 seconds to activate the necessary ignition, accessory outputs and interface
module, to leave the vehicle running and activate Turbo Timer Mode.
2-15 Turbo Timer Mode
“
Start Timer
”
: CM900AS ONLY This feature will allow the user to customize the
process used to start the Turbo Timer.
FO1
–
Last Door Closed (doors lock before shutting down): (default) (actions required within 5
minutes) This option will start the Turbo Timer once the last door/zone has closed and lock the doors a
few seconds BEFORE the timer ends and the engine shuts off. NOTE: a door input must be
connected to allow Turbo Timer to continue to run after exiting the vehicle.
FO2
–
Last Door Closed AND LOCK command: (actions required within 5 minutes) This This option
will start the Turbo Timer once the last door/zone has close AND a LOCK command has been sent.
NOTE: a door input must be connected to allow Turbo Timer to continue to run after exiting the
vehicle.
FO3
–
10 seconds after the Last Door Closed OR LOCK command: (actions required within 5
minutes) This option will start the Turbo Timer 10 seconds after the last door/zone has close (allowing
the user to access other parts of the vehicle in case there are belongings that need to be removed before
the turbo time starts) OR after the last door is closed and a lock command is sent. NOTE: a door input
must be connected to allow Turbo Timer to continue to run after exiting the vehicle.
FO4
–
Last Door Closed (doors lock after shutting down): (default) (actions required within 5
minutes) This option will start the Turbo Timer once the last door/zone has closed and lock the doors a
few seconds AFTER the timer ends and engine shuts off. (this can be used when the vehicles door will
not lock properly while the remote start is shutting down) NOTE: a door input must be connected to