Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2016 Fi rst ech ,
LLC.
Page 36
FO2 - Anti Grind only: This option will allow the Starter Kill wire to provide a negative output when
the system is remote started which can be used to enable starter interrupt and prevent the user from
grinding the starter during secure remote start take over.
FO3 - Anti Grind and passive starter interrupt: This option will allow for Starter Kill wire to provide a
negative output when the system is remote started, or the passive starter interrupt is engaged. This will
prevent the user from grinding the starter during secure remote start take over, and enable starter interrupt
45 seconds after the ignition has been turned off.
3-07 Siren Duration: CM900AS ONLY This feature changes the duration of the siren during full alarm.
FO1 - 30 seconds: this option will provide 30 seconds of output (+) on the siren wire (brown CN3)
during full alarm.
FO2 - 60 seconds: this option will provide 60 seconds of output (+) on the siren wire (brown CN3)
during full alarm.
FO3 - 120 seconds: this option will provide 120 seconds of output (+) on the siren wire (brown
CN3) during full alarm.
FO4 - Chirps for 20 seconds: this option will provide 20 seconds of pulsed output (+) on the siren
wire (brown CN3) during full alarm.
3-08 Horn output: This feature controls the horn output behavior during Arm, Disarm, and Remote Start.
(POC 7 White wire or POC setting #8)
FO1 - On double lock only: (default) this option is designed to simulate a factory keyless entry system
by providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.
FO2 - On lock and Unlock only: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
FO4 - On double lock and Start: this option is designed to simulate a factory keyless entry system by
providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition, it will provide a horn output
pulse with remote start command and remote started confirmation.
3-09 Siren output: CM900AS ONLY This feature controls the siren (+) output behavior during Arm, Disarm, and
Remote Start.
FO1 - On lock, Unlock, and Start: (default) this option will provide a (+) siren output pulse (based
on the option selection of feature 3-02) with each lock, unlock, remote start command and remote
started confirmation.
FO2 - On double lock only: This option is designed to simulate a factory keyless entry system by
providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.
FO3 - On lock and Unlock only: this option will provide a (+) siren output pulse (based on the option
selection of feature 3-02) with each lock or unlock confirmation.