Alarm and Starter System
www.firstechdata.com
CM900 Master Guide
Copyright 2016 Fi rst ech ,
LLC.
Page 42
SO4- Cold Start Temperature: (Feature 2-08 must first be set to option 4.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between -30 ~ 0 [°C] / -22 ~ 32 [°F] with a default temperature of -15°C / 5°F default for the Cold Start
Timer mode activation
SO5- Hot Start Temperature: (Feature 2-09 must first be set to option 4.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between 20°C ~ 40°C / 68°F ~ 104°F with a default temperature of 40°C / 104°F default the Hot Start
Timer Mode activation
SO6- Defrost Temperature: (Feature 3-13 must first be set to option 3.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between 0°C/32°F ~ 13°C/55°F with a default temperature of 6°C/42°F for the defrost activation
Special Option Group 2
This special option group allows you to determine the output type of the POC wire
you’re using
. For example,
if you want to set POC #5 (default setting status out with setting value of 0) to Aux 1, you will need change
special option 5 to setting value 10. This must be done with the OP500.
POC 1 - Green
/White •
Parking Light Output: (default setting value 0) This channel will provide a
250mA (-) negative output when the CM900 parking lights output is generated
(function also
POC setting 1)
POC 2 - Blue/Green
• Lock:
(default setting value 0) This channel will provide a 250mA output with
the lock/arm command.
(function also POC setting 25)
POC 3 -
Blue •
Unlock: (default setting 0) This channel will provide a 250mA output with the
unlock/disarm command.
(function also POC setting 26)
POC 4 -
Black • GWR (ground when running aka status output):
(default setting value 0) This channel
will provide a 250mA output with the remote start activation command and continue to provide
output until 100mS after the remote start process has shut own.
(function also POC setting 5)
POC 5 -
Orange • FAA (Factory Alarm Arm):
(default setting value 0) This channel will provide a
250mA output with the lock/arm command. Note: the CM900 will provide this output approx.
100mS before the unlock output.
(function also POC setting 6)
POC 6 -
Orange/White • FAD (
Factory Alarm Disarm): (default setting value 0) This channel will
provide a 250mA output with the unlock/disarm command.
Note: the CM900 will provide this
output approx. 100mS before the unlock output. (function also POC setting 7)
POC 7 -
White • Horn: (
default setting) This channel will provide a 250mA output when Horn is triggered.
(function also POC setting 8)
POC setting value description (SV)
SV 0
–
DEFAULT SETTING by wire
SV 1 -
Parking light:
provides a 250mA (-) negative parking light output on any POC programmed with
this setting.
SV 2 -
Starter:
provides a 250mA (-) negative starter output on any POC programmed with this
setting.
SV 3 -
Ignition:
provides a 250mA (-) negative ignition output on any POC programmed with this
setting.