background image

ISSUE 3 | MAy 2019 | PAGE 3 OF 4

4.

MOUNTING

Choose a vertical surface near approved ground but away from down spouts, permanent water

sprinklers, and other water sources.

To wall-mount the unit, select #8 wood screws (and washers, if needed behind screw head), or

hardware appropriate for the wall surface 

(Figure 2)

.

 

Figure 2

 — Mount the Unit

5.

GROUND THE UNIT

Step 1: 

Open cover.

Step 2: 

Pierce grommet and feed #6 AWG ground wire into the unit. Ground to the ground

stud or optional ground lug.

Figure 3 — Grounding and Feeder Cable Installation

Wall-mount

Conduit-mount

TPA-3690

Use cable tie or 

large hose clamp.

#8 Wood screw,

add washer if needed.

Ground Wire

Feeder Cable

Open cover 

using can wrench

 

Strain-relief Clamp x 2  

Use spacers to prevent  

crushing cable 

Summary of Contents for Z176SFTTX

Page 1: ...nts 2 TOOLS AND MATERIALS The following may be required for installation Can wrench Hammer Standard screwdrivers 1 4 in x 4 in and pocket size 2 8 Mounting screws wall mount only Needle nose pliers 2 Flat washers for mounting screws wall mount only 2 Large tie bands or cable ties conduit mount only Backplate Ground Stud Entry Grommets Fiber Management Spool Mounting Stud Lower Mounting Ear Adapter...

Page 2: ... when working with severed armor There will be a sharp edge where armor is cut To minimize the chance of injury from the cut armor cover the exposed edge with a wrap of electrical tape To minimize the chance of injury from sharp bladed tools always cut away from yourself and others Dispose of used blades and armor scrap properly DANGER Fiber Optic Cleaning Fluid can cause irritation to eyes on con...

Page 3: ...te for the wall surface Figure 2 Figure 2 Mount the Unit 5 GROUND THE UNIT Step 1 Open cover Step 2 Pierce grommet and feed 6 AWG ground wire into the unit Ground to the ground stud or optional ground lug Figure 3 Grounding and Feeder Cable Installation Wall mount Conduit mount TPA 3690 Use cable tie or large hose clamp 8 Wood screw add washer if needed Ground Wire Feeder Cable Open cover using ca...

Page 4: ... grommet and insert cable into the unit Remove strain relief hardware with a can wrench Strain relieve with the clamp as shown in Figure 3 Step 2 If splicing is required splice to pigtails per the instructions provided with the splicing equipment Store fiber in the splice organizer and fiber management spool Figure 4 Step 3 Route slack around the perimeter of the unit securing to the lances with c...

Reviews: