6
FISCHER
MINIMAX
SERIES
PROCEDURE
9
Potting of the insulator tube through the hole
(upper limit =
blue line
).
Insulator tube can be pre-heated if necessary.
We recommend to use a heat shrinkable sleeve
to cover the filling-hole to avoid potting material
coming out of the hole once potted.
Curing time and conditions according to your
potting material.
10
Put the O-rings on the contact block
(with grease) and on the housing.
11
Initial setup
Make sure the support tool (130254) is properly
centered on the table press (130257) using the
alignment tool provided.
Insertion of the insulator tube with the press.
Insert the insulator tube into the housing with the
multifunction press until it clips on.
Use the appropriate tool set for Minimax 08
(130253) or Minimax 06 (130252).
“tool 1” for MP11
“tool 2” for MR50
“tool 3” “Housing” facing up
Make sure to align the nose of the insulator with
the housing before the insertion operation.