Warnings and error messages
Page 160 - Chapter 5: Warnings and error messages
14.2.13
5.1.2 Warning messages
All warning messages defined for the Panda iControl 2 and the corresponding display output are compiled in the
subsequent table.
Fig. 5.1.2-1: Warning messages
5.2
Faults
Error messages are issued when the monitored variable, e.g. a temperature, reaches the defined fault threshold.
With the temperature sensors, a loose connection or a broken cable will result in a fault, as well, and cause the
generator to shut down.
An error message is typically preceded by a warning, as the warning threshold is reached before the fault threshold.
Error messages are output on the Panda iControl2 panel display in the form of the error text shown on a cleared
display page. Faults do not become active until the time between reaching the fault threshold and the defined delay
has expired.
Faults result in the generator shutting down. If a fault occurs due to the battery voltage being too low, the controller is
completely shut down to prevent the battery from discharging too much.
Examples of an error message on the display:
Fig. 5.2-1: Fault: „Cylinder head temperature out of range“
Fault: „Exhaust manifold temperature out of range“
(broken cable)
Fig. 5.2-2: Fault: „STARTING FAILS“, start-up process was not
successful
Fault: „Winding“, winding temperature too high
Warning message on the display
Meaning of warning message
„HIGH“ flashes, alternating with the temperature value of the cylinder head
Cylinder head temperature is too high, the warning threshold
was reached
„HIGH“ flashes, alternating with the temperature value of the winding
Winding temperature is too high, the warning threshold was
reached
„HIGH“ flashes, alternating with the temperature value of the exhaust manifold
Exhaust manifold temperature is too high, the warning
threshold was reached
„LOW“ flashes, alternating with the voltage value of the starter battery
Starter battery voltage is too low, the warning threshold was
reached
Summary of Contents for Panda 4800i PMS
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Page 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Page 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Page 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Page 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Page 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...