General Instructions and Regulations
Seite/Page 22 - Kaptitel/Chapter 1: General Instructions and Regulations
14.2.13
1.6.1.5 Safety instructions concerning cables
Cable types
It is recommended to use cables that are in compliance with the standard UL 1426 (BC-5W2) with type 3 (ABYC
section E-11).
Cable cross-section
The cable shall be selected taking into account the amperage, cable type, and conductor length (from the positive
power source connection to the electrical device and back to the negative power source connection).
Cable installation
It is recommended to install a self-draining cable conduit classified as V-2 or higher in compliance with UL 94 in the
area of the cable guide inside the capsule. It must be ensured that the cable guide is not routed along hot surfaces
such as the exhaust manifold or the engine oil drain screw but instead is installed free from any influence due to
friction and crushing.
1.6.2 Recommended starter battery sizes
Use only batteries approved by the manufacturer as starter batteries.
Use the battery capacity recommended by the engine manufacturer.
1.6.3 Important instructions for batteries - starter and/or traction batteries
ATTENTION!!! Start-up
:
Installation of battery connection lines.
Observe the instructions installation guidelines of the battery manufacturer.
Observe the regulations „ABYC regulation E11 AC and DC electrical systems on boats“, as EN
ISO 10133:2000 „Small craft -- Electrical systems -- Extra-low-voltage DC installations“, as
applicable!
The battery compartment and the corresponding installation shall be dimensioned
adequately.
The batteries can be separated mechanically or with an adequate power relay.
ATTENTION!
Prior to installation, verify that the voltage of the starter battery complies with the start-up system
voltage.
e.g. 12 V starter battery for 12 V start-up system
e.g. 24 V starter battery for 24 V start-up system (e. g. 2x 12 V in series)
Summary of Contents for Panda 4800i PMS
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Page 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Page 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Page 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Page 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Page 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...