Maintenance Instructions
14.2.13
Panda_4800i PMS_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 97
Fig. 6.6-4:
9. Measure the water temperature with a suitable tempera-
ture measuring instrument.
10.
The thermostat must be completely open at 50 °C water
temperature (for the salt water version) or at 70 °C water
temperature (for the fresh water version).
Fig. 6.6-5:
Example: Thermostat completely opened (see arrow).
Fig. 6.6-6:
Example: Thermostat closed (see arrow).
Fig. 6.6-7:
11.
Remove deposits and gasket residues on the cylinder
head (5) and on the thermostat housing (2); in doing so,
ensure that no dirt gets into the water channel in the cylin-
der head.