FISCHER Mess- und Regeltechnik GmbH
Technical Data | 6
BA_EN_MA15_ATEX
25 / 36
6.3.3.2 Version with DIN connection flange
The dimensions stated apply for all housing models NG100 and NG160.
h
DN
Ød2
LK
ØD
NG
Fig. 15:
Connection flange
Measuring range ≤ 400
mbar
DN
PN
ØD
Ød2
h
LK
Ø
No.
Thread
20
40
157
58
111
75
4
M12
25
40
157
68
110
85
4
M12
50
40
165
102
108
125
4
M16
Measuring range ≥ 0.6
bar
20
40
105
58
106
75
4
M12
25
40
115
68
103
85
4
M12
50
40
165
102
108
125
4
M16
6.3.3.3 Version with ANSI connection flange
Dimension drawing, see Version with DIN connection flange [
}
25]. The di-
mensions stated apply for all housing models NG100 and NG160.
Measuring range ≤ 400
mbar
ØD
Ød2
h
LK
Ø
No.
Thread
1ʺ
150 lbs
157
50.8
118
79.2
4
½-13 UNC
1ʺ
300 lbs
157
50.8
120
88.9
4
⅝-11 UNC
2ʺ
150 lbs
157
91.9
123
120.7
4
⅝-11 UNC
3ʺ
150 lbs
165
92.1
114
127
8
⅝-11 UNC
Measuring range ≥ 0.6
bar
1ʺ
150 lbs
108
50.8
118
79.2
4
½-13 UNC
1ʺ
300 lbs
123
50.8
124
88.9
4
⅝-11 UNC
2ʺ
150 lbs
152
91.9
107
120.7
4
⅝-11 UNC
3ʺ
150 lbs
190.5
127
119
152.4
4
Ø19.1