2 | Product and functional description
FISCHER Mess- und Regeltechnik GmbH
8 / 36
BA_EN_MA15_ATEX
2.2.1 Type plate
This type plate serves as an example of the information that is stated. The data
shown is purely fictive, but does correspond to the actual conditions. For more
information, please see the order code at the end of these instructions.
Article no.
Measuring range
P max
Prod. - No.
Install vertically
MA15F83HV87L011B
0...400 mbar
40 bar
587016.01.002
Serial number
Only connect to certified intrinsically safe circuits.
max. voltage:
Max. power:
Max. capacity:
max. output:
Max. inductivity
30 V
200 mA
800 mW
60 pF
4 µH
Tu 60°C
T medium in the device max. 85°C
Reference no.: 8000389448
0044 TÜV NORD 2014/34/EU
max.
II 2G c 95°C IP65
Limit data
Supply circuit
ATEX code
Notified office
Article no.
Measuring range
P max
Prod. - No.
MA15F83HV87L0100
0...400 mbar
40 bar
587016.01.002
Serial number
Contact function
KE21M210AH2
Made in Germany
4 1 2
Zero position
Switching output
U max :
250V AC/DC
I max :
1A ΩLoad
P max :
30W750VA
Built-in contacts
Built-in contacts
Technical data
Fig. 3:
Type plates with and without contacts
2.3 Intended use
The units may only be used for the purpose stipulated by the manufacturer.
The units serve to measure over-pressure and under-pressure in industrial ap-
plications in areas at risk of explosion acc. to directive 2014/34/EU.
The optional installed switch elements are low-action contacts, mechanical
magnetic spring contacts, inductive proximity switches in a slotted design or ca-
pacitive rotation angle encoder.
(1)
If the set limit values are exceeded, the out-
put power circuits are opened or closed.
The corresponding setup regulations are to be considered for each application
case.
(1)
Please see the information in the order code.