Problem
Possible Causes
What To Do
Total Compartment
Warm.
* PC duct blocked.
- Defrost evaporator chassis.
- Check for door seal.
* Evaporator ice up.
- Check defrost element, check continuity.
- Check door seal / door left open.
* No refrigeration.
- Does compressor run? If no, check power
supplies. If yes, check refrigeration system.
If running, check for live frost/fully flooded
evaporator. If not, check for leak.
* Fans not working.
- Check for fault code (refer to Sections 10.1.1
- Is there a 12Volt supply, PC light working?
- If yes, check fan connection(s) at fan end, also
at power/control module end of the harness.
- If no, check for power/control module failure.
* Power/control module
failure.
- Are lamp / interface LED’s working?
- If not, check display module connection.
- If OK, is compressor running?
- If not, replace power/control module.
FC TOO COLD
Total compartment too
cold.
* FC sensor location.
- Check set temperature.
Sensor clipped and located in correct
position?
* Faulty sensor.
- Check calibration of sensor ice point using
interface binary (refer to Sections 10.1.5 or
10.2.3) or refer to thermistor resistance table
(refer to Section 4.22).
* PC fan not going.
- Check for fault code (refer to Sections 10.1.1
- Check for mechanical obstruction.
- Check polarity.
- Check for broken wires.
- Replace fan.
FC TOO WARM
Bottom warm top frozen.
* Iced up evaporator.
- Check defrost element is working, replace if
faulty.
- Check doors are sealing or have they been left
open? Adjust and advise customer.
- FC fan jammed? Clear restriction, replace fan
if necessary.
- Check defrost sensor position, reposition onto
chassis if not already there.
Total compartment warm.
* PC fan not going.
- Check for fault code (refer to Sections 10.1.1
- Check for mechanical obstruction.
- Check polarity.
- Check for broken wires.
- Replace fan.
* No refrigeration.
- Does compressor run? If no, check power
supplies. If yes, check refrigeration system. If
running, check for live frost / fully flooded
evaporator, if not, check for leak.
Summary of Contents for 635 Active Smart
Page 1: ...321144 Service Manual 635 680 790 900 Active Smart Refrigerator Freezer R134a R600a Systems...
Page 2: ...321144 2...
Page 96: ...321144 96 Photo 12 22 5...
Page 100: ...321144 100 Diagram 12 25...
Page 108: ...321144 108 13 11 Embraco Compressor Fitted With External Overload Diagram 13 11...
Page 114: ...321144 114 14 2 Non Ice Water Models Wiring Diagram...
Page 116: ...321144 116 14 4 Ice Water Models Wiring Diagram...
Page 117: ...321144 117 14 5 900 Models Power Control Module Wiring Connections Reciprocating Compressor...
Page 118: ...321144 118 14 6 900 Models Wiring Diagram Reciprocating Compressor...
Page 119: ...321144 119 14 7 900 Models Power Control Module Wiring Connections VC Compressor...
Page 120: ...321144 120 14 8 900 Models Wiring Diagram VC Compressor...
Page 121: ...321144 121 14 9 B Model Wiring Route Diagram 14 9...
Page 122: ...321144 122 14 10 T Model Wiring Route Diagram 14 10...
Page 145: ......