321144
72
10.2.5 Data Download
To retrieve information from the power/control module, one of the following is required:
•
A Light Pen (part number 425930) and a Cassiopeia Smart Tool.
•
A Light Pen (part number 425930) and a laptop computer with the
Fisher & Paykel Smart Tool
diagnostic program loaded.
The steps to download data are:
1a.
Press and hold the
MODE
button (a short beep will sound).
1b.
Whilst still holding the
MODE
button, briefly press the
TEMPERATURE
UP
button (a short beep will
sound). This enters diagnostic mode.
Steps
1a
and
1b
need to be completed within 8 seconds.
2.
Press the
TEMPERATURE
DOWN
button once; this enters data download mode.
A red LED turns on and should be visible on the display.
3.
Place the Light Pen over the top of the red LED until downloading is complete.
4.
Return to normal operation by pressing the
MODE
button.
If additional help or information is required, please refer to the instructions provided with the Smart Tool, or
ask your Technical Representative.
10.2.6 To Manually Force A Defrost
To manually force a defrost, the steps are:
1a.
Press and hold the
MODE
button (a short beep will sound).
1b.
Whilst still holding the
MODE
button, briefly press the
TEMPERATURE DOWN
button (a long beep
will sound).
Steps
1a
and
1b
need to be completed within 8 seconds.
1c.
Repeat step
1b
and the cabinet will go directly into defrost mode. If the compressor is running, it will
be heard to stop.
NOTE:
If the
MODE
and
TEMPERATURE DOWN
buttons are pressed only once, the forced defrost will not
occur when the compressor cycles off.
2.
To check if the appliance is in defrost mode, repeat step
1a
and
1b
.
If a long beep sounds, then the defrost cycle has started.
3.
To exit manual defrost mode, turn the refrigerator off at the power supply, and then while pressing the
MODE
button, switch the refrigerator on again at the power supply. If this is not done, the refrigerator
will automatically exit from the manual defrost mode when the defrost is completed.
NOTE:
The defrost cycle will not
start
if the defrost sensor is above +8
O
C (46
O
F) as this is the termination
(or cut-out) temperature for the defrost.
The
defrost cycle follows a predefined sequence. Refer to Section 4.3 for details of the defrost cycle.
10.2.7 Show Room Mode
Enter the diagnostic mode (press
MODE
and
TEMPERATURE UP
buttons together) then hold the
TEMPERATURE UP
button only for 3 seconds. The Show Room Mode will be entered, which turns off the
normal system control leaving only the PC light operating with no door alarms. There will be a “long” beep
and while the doors are opened the LED display will go through an attention grabbing sequence unless
buttons are pressed, at which time the display will respond as normal. 8 seconds after the last button press
the display sequence will continue. The interior light will switch off after 5 minutes and can only be re-
activated by closing and opening the PC door. The mode may be exited by switching off the appliance at the
power supply.
Summary of Contents for 635 Active Smart
Page 1: ...321144 Service Manual 635 680 790 900 Active Smart Refrigerator Freezer R134a R600a Systems...
Page 2: ...321144 2...
Page 96: ...321144 96 Photo 12 22 5...
Page 100: ...321144 100 Diagram 12 25...
Page 108: ...321144 108 13 11 Embraco Compressor Fitted With External Overload Diagram 13 11...
Page 114: ...321144 114 14 2 Non Ice Water Models Wiring Diagram...
Page 116: ...321144 116 14 4 Ice Water Models Wiring Diagram...
Page 117: ...321144 117 14 5 900 Models Power Control Module Wiring Connections Reciprocating Compressor...
Page 118: ...321144 118 14 6 900 Models Wiring Diagram Reciprocating Compressor...
Page 119: ...321144 119 14 7 900 Models Power Control Module Wiring Connections VC Compressor...
Page 120: ...321144 120 14 8 900 Models Wiring Diagram VC Compressor...
Page 121: ...321144 121 14 9 B Model Wiring Route Diagram 14 9...
Page 122: ...321144 122 14 10 T Model Wiring Route Diagram 14 10...
Page 145: ......