55
Is door
magnet in
place?
Switch product off and
then on at power outlet
to remove from any
special modes
Place diagnostics
into input/output
mode. Refer
Section 6.2.4
If available, a Smart Tool data
download will verify door switch
failures by very high door open
counts V actual openings
Replace reed
switch
Repair
Yes
No
Yes
No
Does FC door
L.E.D. switch on &
off as FC door is
opened and closed?
Does PC light
switch on & off as
PC door is opened
and closed?
Are reed switch
harness connections
at power/control
module OK?
Refit door magnet
No
Yes
No
10.8 Door Switch Not Operating