58
When defrost sensor
r8 degrees C (46
degrees F) the compressor
will start
Has the
system gone
into defrost
mode?
Is current
being drawn
by defrost
element?
Yes
Check compressor
and system for
leaks/blockages and
repair as required
Yes
No
Remove FC cover.
Is there a full frost
pattern on the
evaporator?
Yes
10.12 Compressor Will Not Run And Is Hot To Touch
10.13 Compressor Electrical Tests
OK?
Refit original
electronic
module/inverter
Are
compressor
winding
resistances
OK?
OK?
Substitute
power/control
module
Yes
No
Replace
compressor
No
Are electrical
connections
to
compressor
OK?
Substiute electronic
module/inverter
Repair connections
OK?
Refit replacement
electronic
module/inverter
No
Yes
Yes
No
Problem solved
Yes
Yes
Summary of Contents for 790 Active Smart
Page 1: ...790 ACTIVE SMART REFRIGERATOR FREEZER 517800...
Page 2: ...2...