VENTING REQUIREMENTS

Attention should be given to ensure that any applicable regulations concerning the 
discharge of exhaust air are fulfilled.
This rangehood is designed to operate with a Fisher & Paykel external blower with the 
exhaust air ducted externally from the kitchen. 

External blower rangehood installation is different from internal blower rangehood 
installation, please refer to the external blower installation guide for details.

External blower

Roof

Ducting

Power cords

Ceiling

Summary of Contents for CONTEMPORARY HP60IDCHEX3

Page 1: ...INSTALLATION GUIDE NZ AU INTEGRATED INSERT RANGEHOOD WITH EXTERNAL BLOWER CONTEMPORARY HP60IDCHEX3 HP90IDCHEX3...

Page 2: ......

Page 3: ...rnings 4 Parts supplied 6 Prior to installation 7 Product dimensions 8 Cutout dimensions 10 Installation height 12 Venting requirements 14 Prepare rangehood 16 Connect rangehood 18 Parts and accessori...

Page 4: ...fire or injury to persons Do not immerse cord or plugs in water or other liquid WARNING Weight Hazard Failure to follow this advice may result in personal injury The appliance is heavy Please ensure...

Page 5: ...must only be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard z All ducting must comply with local requirements and building codes z Attention s...

Page 6: ...6 PARTS SUPPLIED INSTALLATION GUIDE NZ AU INTEGRATED INSERT RANGEHOOD WITH EXTERNAL BLOWER HP60IDCHEX3 HP90IDCHEX3 models Installation guide 1 Rangehood 1 200 mm ducting adapter 1 8 mm screw 4...

Page 7: ...te z Check all functions are working z The rangehood surfaces can be damaged during installation if grazed or knocked by tools Please take care to protect the surfaces during installation z Protect th...

Page 8: ...8 PRODUCT DIMENSIONS PROFILE FRONT BOTTOM VIEW A b c d i h j k m l f g e PLAN Ducting adapter...

Page 9: ...sis 492 792 G Depth of the chassis 255 255 H Height of the chassis 120 120 I Width of top surface of chassis 240 240 J Distance from centre of ducting outlet to back of chassis 145 145 K Distance from...

Page 10: ...10 CUTOUT DIMENSIONS 60cm model CUTOUT DIMENSIONS HP60 MM A Overall width of the cutout 500 B Overall depth of the cutout 260 A b...

Page 11: ...11 CUTOUT DIMENSIONS 90cm model CUTOUT DIMENSIONS HP90 MM A Overall width of the cutout 800 B Overall depth of the cutout 260 A b...

Page 12: ...height indicated in the table above Minimum installation height may be greater if required by the cooktop refer to your cooktop installation instructions Installation at the minimum height will impro...

Page 13: ...used also influence condensation For example aggressive boiling on high cooktop heat settings like PowerBoost increases the rate at which water is evaporated increasing the likelihood of condensation...

Page 14: ...d This rangehood is designed to operate with a Fisher Paykel external blower with the exhaust air ducted externally from the kitchen External blower rangehood installation is different from internal b...

Page 15: ...ore connecting the rangehood to the power supply ensure the voltage and frequency indicated on the rating plate match that of the installation location MODEL FREQUENCY VOLTAGE HP60 50 Hz 230 V HP90 50...

Page 16: ...ucting adapter onto the hood and screw it in place using the screws supplied Ensure the arrows on the hood and ducting adaptor align 1 2 Open the perimeter plate and remove the filters pull the catch...

Page 17: ...FIT RANGEHOOD Lift the rangehood and fit into the cabinetry until the spring loaded brackets clips hold the product in place 1 2 Secure the rangehood by tightening the 4 brackets clips x4 x4 2 3 2 2 2...

Page 18: ...minium tape Install the external blower if not already installed refer to rangehood external blower installation guide Reinstall the filters Place the filter into the support at the rear of the rangeh...

Page 19: ...EHOOD Reattach the perimeter plate Slide the the perimeter plate onto the bracket and tighten the screws 4 Connect to the external blower and plug the rangehood in 5 External blower Roof Ducting Power...

Page 20: ...20 PARTS AND ACCESSORIES ITEM REFERENCE NUMBER Flexible ducting 200mm 6m 792961...

Page 21: ...le ducting has been pulled taut and any excess removed if required Power plug switch is accessible to the customer Product is plugged in and power switched on Operation of the product has been tested...

Page 22: ......

Page 23: ......

Page 24: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications...

Reviews: