SAFETY AND WARNINGS
Gas requirements
z
This appliance can be used with any brand of 20lb LP gas tank provided it is
compatible with a proper retention device (not supplied).
z
This appliance is set for use with either LP or NG, decided at the point of purchase.
z
The LP gas cylinder must be:
z
Designed for use with a Type 1 system only.
z
Constructed and marked in accordance with the Specifications for LP gas Cylinders
of the U.S. Department of Transportation (D.O.T.) or the Standard for Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/
CSA-B339
z
Provided with a listed overfilling prevention device.
z
Provided with a cylinder connection device compatible with the connection for
outdoor cooking gas appliances
z
The cylinder must be provided with a shut-off valve terminating in an LP gas supply
cylinder valve outlet specified, as applicable, for connection Type 1.
z
Do not change the regulator/hose assembly from that supplied with the unit or attempt
to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve
assembly.
z
Never use a cylinder with a damaged valve. The cylinder that is used must have a collar
to protect the cylinder valve.
z
An installer-supplied gas shut-off valve must be installed in an easily accessible location
z
All installer supplied parts must conform to local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CSA-B149.1 Natural
Gas Installation Code or CSA-B149.2 Propane Installation Code.
z
In Massachusetts such shut-off valves should be approved by the Board of State
Examiners or Plumbers & Gas Fitters.
z
All pipe sealants must be an ap proved type and resistant to the actions of LP gases.
Never use pipe sealant on flare fittings.
z
A dented or rusty LP tank may be hazardous and should be checked by your LP
supplier.
z
Always check for leaks after every LP tank change.
z
For LP units, check for leaks with a full cylinder.
z
Do not use the appliance until all connections have been checked and do not leak.