Installation instructions
18
Connecting to supply
Fig.10 Connecting supply
Plugged
Tapping
Shut-off valve
Apply pipe
compound to
all male threads
Fig.11 Tightening supply connections
Using two adjustable
wrenches tighten all
connections
Important!
Do not over tighten the connections.
Test for gas leaks
WARNING!
NEVER use an open flame to test for gas leaks.
■
■
Turn on the gas (open the gas shut off valve).
■
■
All connections should be checked for leaks with a soapy, or equivalent solution. Apply a soap
(or equivalent) solution to the connection points. If leaks are found, close the shut-off valve,
re-tighten the joint, then repeat the test.
Note: Do not use a solution that contains ammonia. This may cause damage to the brass fittings.
Open gas valve
Fig.12 Testing for gas leaks