INTRODUCTION 

The service manual covers the implementation of electronic control to Vertical Freezers. 

1.1 

Electronics 

Changes to the single temperature models are that an electronic module has replaced the defrost 
timer and relay.  A variable resistor replaces the thermostat. 
 
With the introduction of the electronic module, some of the current functions of the product will also 
change.  These will be covered under the appropriate headings. 
 
The  operational  component  such  as  the  evaporator  has  also  changed  from  the  corrugated  type 
evaporator to the new Showa fin on tube evaporator.  The condenser and cabinet do not change. 
 

1.2 

Product Specification 

1.2.1 

Compressors 

Product Model 

Compressor Part Number 

Refrigerant Charge 

E373/450

 

207119

 

100 grams R134a 

 

1.2.2 

Compressor Specification 

Brand 

Matsushita 

Model 

SF48C91RAW5 

Part Number 

207116 

Volts 

230/240 

Hertz 

50 

Nominal BTU 

470 

Output Watts 

138 

Run Current (Amps) 

0.50 

Start Resistance (Ohms) 

28.50 

Run Resistance  (Ohms) 

18.20 

Relay 

F&P Electronic 

Overload Part Number 

 

Run Capacitor Part Number 

207164 

 

1.3 

Condenser Layout 

The  new  compressors  have  no  oil  cooler  lines;  therefore  the  re-routing  of  the  condenser  is  as 
follows: 
Discharge  line  from  the  compressors  runs  directly  to  the  waste  water  tray  and  then  into  the 
condenser on the back panel.  From the back panel it enters the LH side condenser (viewed from 
the rear), through the cross rail heater (if applicable) then into the RH side condenser, then into the 
filter dryer.  The remaining layout remains unchanged. 

Summary of Contents for E373

Page 1: ...517672 Electronic Single Temperature Refrigerators Models E373 E450...

Page 2: ...3R 1 FP WH SG 25646 RF450SLDW1 FP AA 25645 RF450SRDW1 FP AA 25647 RF450SRDW1 FP SG HK 23957 E450L D FP WH 24855 E450LW1 FP AA 25051 E450LW1 FP AA 22170 E450L D FP WH 05 22105 E450L D FP WH 07 22101 E4...

Page 3: ...Alarm 7 2 12 Compressor Starting 7 3 FAULT CODES 7 3 1 Fault Code Table 7 3 2 To Disable Alarm 9 3 3 To Manually Force A Defrost 9 4 SERVICE PROCEDURES 10 4 1 Control Module 10 4 2 Compressor Overload...

Page 4: ...1 2 1 Compressors Product Model Compressor Part Number Refrigerant Charge E373 450 207119 100 grams R134a 1 2 2 Compressor Specification Brand Matsushita Model SF48C91RAW5 Part Number 207116 Volts 230...

Page 5: ...m the light to determine whether the door is opened or closed 2 3 Temperature Controller The temperature controller is a variable resistor located in the control box It has replaced the thermostat The...

Page 6: ...controlled by the control module which switches it via a relay The defrost interval can vary from between 8 hours and 16 hours of compressor run time depending on the duration time of the last defrost...

Page 7: ...an audio fault alarm will sound when the door is opened The alarm consists of a number of beeps emitted by the beeper located in the control module The number of beeps emitted indicates the fault as...

Page 8: ...tance Secondary Action Replace control module Fault 10 10 beeps Reason The resistance of the PC sensor is outside the normal range 660 Ohms Primary Action Check the sensor connection at the power modu...

Page 9: ...ds 3 3 To Manually Force A Defrost Open the door push the light plunger in and hold in turn the variable resistor control knob to the warmest setting then turn it to the coldest setting within ten sec...

Page 10: ...move all the connectors from the control module Refit the module in reverse order making sure all wiring is secured in the module and the wiring harness is located in the module slot 4 2 Compressor Ov...

Page 11: ...from the power source Remove duct cover Remove fan cover Disconnect fan terminals off fan and remove sensor from housing Remove two screws holding fan housing and unclip fan housing from evaporator c...

Page 12: ...the evaporator duct cover Reassemble the product in reverse order 4 4 Variable Resistor Unplug the product from the power source Remove control box by removing the two screws holding control box in pl...

Page 13: ...517672 13 5 WIRING DIAGRAM...

Page 14: ...ug overload and control module connections Check start and run windings as per specifications Check run capacitor 6 4 PC Too Cold Check resistance of variable resistor Check resistance of PC sensor as...