Fault 7:
7 beeps
Reason:
The resistance of defrost sensor is outside the normal range (> 45K Ohms).
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Re-terminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 8:
8 beeps
Reason:
The resistance of defrost sensor is outside the normal range (< 660 Ohms).
Primary Action:
Check the 4-way connector at the control module.
Secondary Action: Check sensor resistance.
Re-terminate the 4-way connector.
Tertiary Action:
Replace control module.
Fault 9:
9 beeps
Reason:
The resistance of the PC sensor is outside the normal range.
(> 45K Ohms)
Primary Action:
Check the sensor connection at the power module.
Check sensor resistance.
Secondary Action: Replace control module.
Fault 10:
10 beeps
Reason:
The resistance of the PC sensor is outside the normal range.
(< 660 Ohms)
Primary Action:
Check the sensor connection at the power module.
Check sensor resistance.
Secondary Action: Replace control module
Fault 11:
11 beeps
Reason:
Compressor has failed to start after 5 attempts.
Primary Action:
Check the integrity of the compressor and components.
Replace components if found faulty.
Secondary Action: Replace control module
Fault 12:
12 beeps
Reason:
The control variable resistor has an open circuit fault.
Primary Action:
Check the continuity of the circuit between the variable resistor and the control
module and the connections at the variable resistor and the control module.
Secondary Action: Replace control module
Fault 19:
19 beeps
Reason:
Electronic mismatch between electronics and model of cabinet.
Primary Action:
Replace electronic module and reinitialise.